11
SPECIAL NOTES
1
EQUIPMENT LOAD
2
LOW VOLTAGE CONDITION
When input voltage decrease to 10.5V + 0.5V (24
type is 21V + 1V) the unit will « bip » warning you
that the battery is running low, please stop using the
converter immediatly. If you keep using the converter
when it’s biping the unit will automatically shut down
preventing the battery of running out.
3
BATTERY POLARITY
The input cigarette plug outside is negative, the center
is positive. So the unit is used in a negative ground
vehicle, should not be used in positive ground vehicle.
Do not connect any equipment requiring more than
150W
(CV12-220-150-2B)
and 300W
(
CV12-220- 300-2B
and
CV24-220-300-2B
)
continuously to the unit. The unit has a built-in
protecting circuit. It will automatically shut down if it
is overloaded and will restart once the overload is
removed. Under 150W or 300W the unite will not
operate most power tools and appliances which
produce heat, such as hair dryers, microwave
ovens, toasters...
Note :
when the inrush current reaches maximum,
the product will automatically stop in 0.02 seconds,
and it can only restart by reconnecting.