13.7
SCADA N-Module
Note: Not all functions may be available, those available will depend on your pump model.
Recommended control cable: metric = 0.14sq mm - 2.5sq mm solid and 0.14sq mm - 1.5sq mm stranded.
USA = 26AWG - 14AWG solid and 26AWG - 16AWG stranded. Cable: circular. Max/min outside diameter
to ensure a seal when passed through the standard gland: 9.5mm- 5mm.
The cable section must be
circular to ensure a seal.
Never apply mains power above 130V AC to the terminals within the
SCADA module. Apply the correct signals to the terminals shown. Limit
signals to the maximum values shown. Do not apply voltage across
other terminals. Permanent damage, not covered by warranty, may
result.
The maximum rating on the relay contacts of this pump is 1250VA.
Key to symbols
m-530dun-gb-01
35