Press the
INFO
key again to display the 4-20 mA calibration figures.
Analog Scaling Factor
The Scaling Factor is a method of adjusting the 4-20 mA profile by using a multiplication
factor.
Press
+/-
from the
HOME
screen to access the scaling factor.
Use the
+/-
keys to enter a multiplication factor. A figure of 1.00 will not alter the 4-20 mA
profile. A figure of 2 will double the flow rate output from a specific mA signal. A figure of
0.5 will halve the output.
m-qdos-allmodels-en-07
85