Watson-Marlow 323Dz User Manual
40
17 Drive maintenance
The pump is sealed to IP31 and is suitable for wipe-down cleaning. Do not use sol-
vents, mechanical scourers, strong organic acids, or alkali-based cleaning solutions.
Remove any tubing, detach the pumphead, and wash the pumphead thoroughly with
a mild solution of detergent in water.
Check moving parts of the rotor from time to time for freedom of movement. Lubri-
cate pivot points and rollers occasionally with Teflon lubricating oil.
The pump has a good, broad chemical resistance to inorganic acids, saline solutions,
alkalis, some hydrocarbons and a large number of oils and greases. It is suitable for
wipe-down but not for long-term contact with alcohols. The case may be damaged by
contact with strong acids or strong solvents.
There are no user serviceable parts inside the pump. The unit should be re-
turned to Watson-Marlow or its appointed agents or distributors for
service.
18 Drive part numbers
Drives only
Part number
Drive type
Drive speed
Pumphead
Mains lead
type
036.3183.00U
323Dz
300
-
UK
036.3184.00U
323Dz
400
-
UK
Complete pump assemblies
Part number
Drive type
Drive speed
Pumphead
Mains lead
type
030.3183.RLU
323Dz
300
501RL
UK
030.3184.3DU
323Dz
400
313D
UK
030.3184.4DU
32Dz
400
314D
UK
For US mains lead, replace ‘U’ with ‘A’ at end of part number.
For European mains lead, replace ‘U’ with ‘E’.
U
E
A