Watson-Marlow 323Dz User Manual
36
If you select
Menu
, the pump displays the main menu. See 15
Main menu
.
Batch pause
You can interrupt a batch at any time by pressing
STOP
. The pump stops and offers
four choices:
Unpause
: continue the dose sequence from where it was stopped;
Restart
: start the dose or the batch from the beginning;
Re-calibrate
: re-calibrate
the pump; and
Exit
: abandon the batch and return to the main menu.
Use the
UP
and
DOWN
keys to make a selection. Press
RETURN
to confirm.
Unpause
: If you choose
Unpause
the pump finishes dispensing the current
dose and completes the batch.
Restart
: If you choose
Restart
the pump displays the number of doses in the
batch and the number which have been completed. It offers two choices: restart
the interrupted dose or restart the batch. Use the
UP
and
DOWN
keys to make
a selection. Press
RETURN
to confirm.
Select
Restart dose
and the pump re-dispenses the interrupted dose and
resumes the batch where it was interrupted - as in the example shown
above.