15.4.11 Batch dispensing
If the batch is set to perform more than one dose with a set interval between
doses, the pump operates until all the batch's doses have been dispensed. The dis-
play decrements as each dose is dispensed, showing the number of doses still to be
dispensed. During the intervals between doses - 3 seconds in the example shown -
the time elapsing is counted down to show how much time is left before the next
dose will start.
If the interval is set to zero seconds, the batch can be dispensed in individually
triggered doses by repeated presses on the
START
key. The display decrements as
each dose is dispensed, showing the number of doses still to be dispensed.
When the batch is complete, the pump displays a screen summarising the batch,
and offering two choices: start the batch again or return to the menu screen,
where batch setting changes can be made.
Use the
UP
and
DOWN
keys to highlight
Start
or
Menu
and press
RETURN
.
If you select
Start
, the pump displays the dose size and the number of doses
and waits for the
START
key to be pressed to begin a repeat batch.
Alternatively ...
Just press
START
.
Note
: When a batch is repeated, no opportunity is offered to prime the pump. If
you wish to re-prime the pump, return to the main menu and re-enter the dosing
menu as if it were a new batch.