![Watkiss Plockmatic PowerSquare 224 Service Training Workbook Download Page 8](http://html.mh-extra.com/html/watkiss/plockmatic-powersquare-224/plockmatic-powersquare-224_service-training-workbook_876067008.webp)
Introduction
4
Plockmatic PowerSquare™ 224 - Service Training Workbook
Every exploded diagram is followed by the related part number information. The
part number information is given for the top level assembly, sub-assemblies and
components where available. See FIGURE 3.
Part No.
Item
Description
Qty.
Fig.
FIG.16 - TAMPER GATE FRAME
PSQ SHUTTLE -PSHU
LAST EDIT:18 AUG 09
Fig16
891-648
P.ASSY, (PSQ) TAMPER-GATE FRAME
1
1
891-688
• P.ASSY, (PSQ) TAMPER-GATE TIE BAR
1
1a
180-418
• • SPRING, E-CLIP FOR 4mm GROOVE
6
1b
190-575
• • OILITE, 5ID x 8OD x12LG + MOS2
2
1c
180-078
• • SPRING, 18mm x 9mm Ext., Extra strong
2
1d
266-086
• • SHAFT,(PSQ) ACTIVE-GATE TOP HAT SPACER
2
1e
190-370
• • BEARING, ROLLER 12mmODx8mmIDx3.5mm LG
2
1f
266-087
• • SPACER, (PSQ) GATE 10.50ODX8IDX3LG
1
1g
266-095
• • SHAFT, (PSQ) ACTIVE-GATE TIE BAR
1
•
2
891-647
• P.ASSY, (PSQ) TAMPER PIVOT DRIVE SIDE
1
2a
100-334
• • SCREW, SKT HD CAP, M2.5x10mm STAINLESS
1
2b
160-202
• • WASHER, M2.5 FORM A BZP
1
2c
257-833
• • ST ST, (PSQ) PIVOT LOCATION PLATE
1
2d
266-088
• • SHAFT,(PSQ) ACTIVE-GATE PIVOT PIN
1
•
3
315-775
• PLASTIC,(PSQ) ACTIVE-GATE PIVOT BLOCK
1
4
891-645
• P.ASSY, (PSQ) TAMPER GATE BRACKET
1
5
891-646
• P.ASSY, (PSQ) TAMPER PIVOT PLATE
1
5a
266-088
• • SHAFT,(PSQ) ACTIVE-GATE PIVOT PIN
1
5b
257-833
• • ST ST, (PSQ) PIVOT LOCATION PLATE
1
5c
160-202
• • WASHER, M2.5 FORM A BZP
1
5d
100-334
• • SCREW, SKT HD CAP, M2.5x10mm STAINLESS
1
•
6
160-002
• WASHER, M3 FORM A BZP
2
7
100-326
• SCREW, SKT HD CAP, M3 x 10mm STAINLESS
2
8
165-001
• SHAKEPROOF WASHER, M4 INTERNAL BZP
2
FIGURE 3. Extract from PSHU, Issue 3. Fig.16. Part number information.
Top-level assembly
Sub assembly
Component level
PSQ Site Requirements
Plockmatic PowerSquare™ 224 - Service Training Workbook
45
17.9.1
Online PowerSquare
PSQ
Connecting
Bridge
Input for Mains Power Supply
Maintenance area: 3255 mm, 129"
2755mm, 109"
1870
mm,
74"
Maint
ena
nce a
rea:
2870
mm,
1
13
"
NOT TO SCALE
Stacker