PROBLEMS AND SOLUTIONS 

 

Problem 

Possible cause 

Solution 

1. The timer does not display time 

a. transformer not connected 

a. reconnect 

b. No voltage in electrical outlet 

b. Repair the outlet or use a working outlet 

c. transformer failure 

c. Replace transformer 

d. Electronic plate damaged 

d. Replace electronic plate  

2.  The  timer  does  not  display  the 
correct time 

a. Connection jack disconnected 

a. Try another jack 

b. power failure 

b. Re-set time 

c. Electronic plate damaged 

c. Replace electronic plate  

3.  It  does  not  display  ''softening", 
when the water is flowing 

a. Water flows through the bypass 
and not through the filter 

a. switch the bypass 

b. meter disconnected 

b. reconnect the meter to the electronic board 

c. Meter turbine jammed / stopped 

c. Remove the meter and check if there is some 

foreign material  

d. meter damaged 

d. Replace meter  

e. Electronic plate damaged 

e. Replace electronic board 

4. Control valve starts 
regeneration at wrong time  

a. There has been a power outage 

a. set the correct time in the control valve. 

b. the time set not correctly  

b. set the time correctly 

c. wrong regeneration time 

c. re set regeneration time 

d. Control valve set for immediate 
regeneration 

d. Check the control valve setting of recovery time 

options. 

5. An error with the code number 
 
1001 or E1 – It is not possible 
 to identify the start of 
 regeneration 
 
1002 or E2 – unexpected stop 
1003 or E3 – Motor runs too long, 
out of adjustment trying to reach 
the next regeneration cycle 
position 
 
1004 – Motor runs too long, out 
of adjustment, trying to reach the 
starting position 
 
If some other code shows up, 
contact the manufacturer. 

a. Control valve has just been 
served 

a. for 3 seconds Press NEXT and REGEN or pull-
out wire (black) from the power supply and 
reinsert to set the control valve 

b. control valve jammed 

b. Check piston and spacer block if they are not 
stuck 

c. High drive forces on the piston 

c. Replace piston and spacer block components 

d. control valve plunger is not in 

home

 position 

d. for 3 seconds Press NEXT and REGEN or pull-
out wire (black) from the power supply and 
reinsert to set the control valve 

e. motor is not fully inserted in 
order to achieve the drive gears, 
motor wires damaged or 
disconnected, motor failure 

e. Check motor and wires. Replace motor if 
necessary 

f. The drive label damaged or dirty, 
the mechanism is missing or 
damaged 

f. Replace or clean the drive mechanism. 

g. The drive base inserted into plate 
incorrectly 

g. Thoroughly check the drive bracket 

h. Electronic plate is damaged or 
defective 

h. Replace electronic plate  

i. Electronic plate is incorrectly 
connected to the base of the drive 

i. Make sure that the electronic circuit board is 
properly connected to the drive bracket. 

6. Control valve stopped during 
regeneration 

a. Motor does not run 

a. Replace motor 

b. No voltage in the socket  

b. repair the socket or use working socket  

c. adapter (transformer) damaged 

c. Replace transformer 

d. electronic plate damaged 

d. Replace electronic plate  

e. Faulty actuator or drive cover 
part 

e. Replace actuator or drive cover part 

Summary of Contents for WATEX CMS-10

Page 1: ...info watex eu Tel 371 67381989 www watex eu Installation and operation manual WATEX CMS 8 9 10 12 13 14 WATER SOFTENER Read the instructions carefully before use Watch CMS water softener start up vide...

Page 2: ...a Ganibu dambis 27 k 5 info watex eu Tel 371 67381989 www watex eu 2 CONTENTS INTRODUCTION 3 REQUIREMENTS 3 SPECIFICATIONS 4 SYSTEM MAIN COMPONENTS 5 OPERATION MODES 7 INSTALLATION 8 START UP 15 PROBL...

Page 3: ...another person using your hands Moving by hands it is recommended to grab the top behind the control valve housing the place where the control valve connects to the tank and the bottom behind the blue...

Page 4: ...Width m 0 28 0 28 0 28 0 3 0 46 0 46 Height m 1 14 1 47 1 62 1 57 1 62 1 91 Weight filled with water kg 50 60 70 95 155 195 Connection in out drain inches 1 1 3 4 1 1 1 Clack control unit WSCI 1 WS CI...

Page 5: ...atvia Riga Ganibu dambis 27 k 5 info watex eu Tel 371 67381989 www watex eu 5 SYSTEM MAIN COMPONENTS The softener has three main basic components resin tank Clack control valve and brine tank 2 1 1 Co...

Page 6: ...ufficient to dissolve part of the NaCl regeneration cycle Brine well The brine well is a cylindrical barrier that keeps the salt or potassium chloride away from the safety float and air check valve wh...

Page 7: ...s the resin and large amounts of sodium ions replace the hardness ions accumulated during service 3 Second backwash After brine is completely removed from the brine tank into the resin tank the brine...

Page 8: ...indicating arrows If you look at the filter from the front on the right side is the inflow and on the left side is discharge The filter s connection to the mains outer thread size 1 inch of both input...

Page 9: ...rinsing is not dropping out Secure it Important Make sure the garden hose is not folded because it will reduce rinsing water flow and the filter is likely to have incomplete rinsing which can lead to...

Page 10: ...trol panel is shown in the drawing highlighting the connection point of the reagent supply line The pipeline connection is carried out as follows 1 Unlock the control unit reagent by removing the clam...

Page 11: ...ypass option Directional shut off arrows for flow Normal Bypass Diagnostic mode Shut off mode Radial seals allow side to side and up down minor plumbing misalignments connections need only hand tighte...

Page 12: ...To ensure a continuous supply of electricity from the source located not farther than 2 meters from the water softener Adapter wire must be connected inside the control valve 1 Remove the front cover...

Page 13: ...s made while in programming modes Toggles between available User Display Screens or Allows programmer to advance to the next display screen in programming mode Change variable being displayed in progr...

Page 14: ...WATEX Ltd Latvia Riga Ganibu dambis 27 k 5 info watex eu Tel 371 67381989 www watex eu 14 Setting Time of Day Installer Display Settings...

Page 15: ...iously set data is automatically saved and the programming progresses to the next settings Next press NEXT until the current day is displayed Therefore the setup cycle is closed and all settings are s...

Page 16: ...peration control During operation the normal user display is time of day current flow rate liters per minute remaining capacity cubic meters per hour Each of these can be viewed by pressing NEXT to sc...

Page 17: ...E3 Motor runs too long out of adjustment trying to reach the next regeneration cycle position 1004 Motor runs too long out of adjustment trying to reach the starting position If some other code shows...

Page 18: ...ntrol valve does not make recovery automatically but it does so when REGEN button is pressed a Water flowing through the bypass a Close the bypass b the meter is disconnected b Connect the meter to th...

Reviews: