Reagent tank connection 

The  kit  contains  a  reagent  tank  as  well  as  a  3/8  "connecting  pipe.  The  flexible  plastic  tube  is  placed  in  the  reagent  container 
under the lid. The reagent tank should be placed next to the filter tank. Can be placed on any side of the filter tank. 
The reagent tank has a plug that is placed in the plastic container of the reagent tank. Remove the float and remove the transport 
rubber put on the bottom of the float. Threads do not have to use packaging materials. 
 
Remember! 
The  regeneration  tank  will  need  to  be  filled  with  a  reagent  on  a  regular  basis,  so  it  is  advisable  to  place  it  where  it  is  easily 
reachable. 
The control panel is shown in the drawing, highlighting the connection point of the reagent supply line. The pipeline connection 
is carried out as follows:  

1.Unlock the control unit reagent by removing the 
clamp and removing the reagent attachment elbow. 
2. Pull the pipe through the nut 
3. Place the cylindrical insert on the end of the tube, 
then make two consecutive rings. 
4. Insert the end of the tube into the bend hole to the 
end and tighten with the nut. Manual engagement. 
5. Place the reagent joint in the opening and place the 
clamp. 
Note: The reagent connection elbow has a sealing 
ring, it can be rotated in the desired direction. 
Turning angle is 270

o

6. The end of the second tube is drawn through the 
hole in the side of the reagent tank and added in the 
same manner as in paragraphs 2, 3 and 4. 
 
When the equipment is connected to the water 
supply, drainage and reagent tanks, in the reagent 
container, fill salt tablets (NaCl) in Brine tank. 
 
 

Summary of Contents for WATEX CMS-10

Page 1: ...info watex eu Tel 371 67381989 www watex eu Installation and operation manual WATEX CMS 8 9 10 12 13 14 WATER SOFTENER Read the instructions carefully before use Watch CMS water softener start up vide...

Page 2: ...a Ganibu dambis 27 k 5 info watex eu Tel 371 67381989 www watex eu 2 CONTENTS INTRODUCTION 3 REQUIREMENTS 3 SPECIFICATIONS 4 SYSTEM MAIN COMPONENTS 5 OPERATION MODES 7 INSTALLATION 8 START UP 15 PROBL...

Page 3: ...another person using your hands Moving by hands it is recommended to grab the top behind the control valve housing the place where the control valve connects to the tank and the bottom behind the blue...

Page 4: ...Width m 0 28 0 28 0 28 0 3 0 46 0 46 Height m 1 14 1 47 1 62 1 57 1 62 1 91 Weight filled with water kg 50 60 70 95 155 195 Connection in out drain inches 1 1 3 4 1 1 1 Clack control unit WSCI 1 WS CI...

Page 5: ...atvia Riga Ganibu dambis 27 k 5 info watex eu Tel 371 67381989 www watex eu 5 SYSTEM MAIN COMPONENTS The softener has three main basic components resin tank Clack control valve and brine tank 2 1 1 Co...

Page 6: ...ufficient to dissolve part of the NaCl regeneration cycle Brine well The brine well is a cylindrical barrier that keeps the salt or potassium chloride away from the safety float and air check valve wh...

Page 7: ...s the resin and large amounts of sodium ions replace the hardness ions accumulated during service 3 Second backwash After brine is completely removed from the brine tank into the resin tank the brine...

Page 8: ...indicating arrows If you look at the filter from the front on the right side is the inflow and on the left side is discharge The filter s connection to the mains outer thread size 1 inch of both input...

Page 9: ...rinsing is not dropping out Secure it Important Make sure the garden hose is not folded because it will reduce rinsing water flow and the filter is likely to have incomplete rinsing which can lead to...

Page 10: ...trol panel is shown in the drawing highlighting the connection point of the reagent supply line The pipeline connection is carried out as follows 1 Unlock the control unit reagent by removing the clam...

Page 11: ...ypass option Directional shut off arrows for flow Normal Bypass Diagnostic mode Shut off mode Radial seals allow side to side and up down minor plumbing misalignments connections need only hand tighte...

Page 12: ...To ensure a continuous supply of electricity from the source located not farther than 2 meters from the water softener Adapter wire must be connected inside the control valve 1 Remove the front cover...

Page 13: ...s made while in programming modes Toggles between available User Display Screens or Allows programmer to advance to the next display screen in programming mode Change variable being displayed in progr...

Page 14: ...WATEX Ltd Latvia Riga Ganibu dambis 27 k 5 info watex eu Tel 371 67381989 www watex eu 14 Setting Time of Day Installer Display Settings...

Page 15: ...iously set data is automatically saved and the programming progresses to the next settings Next press NEXT until the current day is displayed Therefore the setup cycle is closed and all settings are s...

Page 16: ...peration control During operation the normal user display is time of day current flow rate liters per minute remaining capacity cubic meters per hour Each of these can be viewed by pressing NEXT to sc...

Page 17: ...E3 Motor runs too long out of adjustment trying to reach the next regeneration cycle position 1004 Motor runs too long out of adjustment trying to reach the starting position If some other code shows...

Page 18: ...ntrol valve does not make recovery automatically but it does so when REGEN button is pressed a Water flowing through the bypass a Close the bypass b the meter is disconnected b Connect the meter to th...

Reviews: