“WATEX” Ltd., Reg. Nr. 40003712811, Ganibu dambis 27 k-5, Riga, LV-1005; Contact information: tel. +371 67381989, e-mail:
[email protected], www.watex.eu
13
4.3.
Regeneration set up after days passed and time of day
Press and hold the
"NEXT"
button and the
“UP”
arrow at the same time, hold for 3 seconds
until:
1) The number "14" flashes in the lower right corner, indicating that the rinsing cycle must
be performed every 14 days. Use the
"UP"
and
"DOWN"
keys to set the desired rinsing
day interval (how many days the filter will rinse). Press the
"NEXT"
button.
2) The arrow and the number "2" will start flashing in the lower left corner. This indicates
the start time of the rinsing cycle at 2.00 at night. Use the
"UP"
and
"DOWN"
keys to set
the desired regeneration start hour. Press
"NEXT"
and use the
"UP"
and
"DOWN"
keys to
set the desired minutes.
3) Press
“NEXT”
to complete the installation and return to normal operation. The display
shows the current time.
4.4.
Manual regenerations
Sometimes it is necessary to perform regenerations faster than the system determines that it is
necessary. This is usually called manual recovery. It is possible that there has been a period when
water has been used more than usual, such as when there have been guests or more laundry, etc.
To start manual recovery with the set delayed recovery time, press and release the “REGEN” button.
The words “REGEN TODAY” will flash on the display, indicating that the system will start
recovery at the pre-set recovery time. If you press the "REGEN" button by mistake, pressing the
button again will cancel the request.
To start manual recovery immediately, press and hold the “REGEN” button for 3 seconds. The
system will start recovery immediately. This request cannot be canceled.
When the system starts recovery, the display will change to show the current recovery cycle. The
system will automatically go through the regeneration steps and set itself to water purification mode
when the regeneration is complete.
4.5.
Operation control
When the system is operating, one of the three displays may appear. By pressing “NEXT”, you can
switch between the displays. There is always time in one of the displays. The second display shows:
number of days remaining or volume remaining (m3). The number of days remaining is the number
of days remaining until the system begins the regeneration cycle. The remaining capacity is the
number of cubic meters that will be purified before the unit begins the regeneration cycle. The third
display shows the current flow rate of purified water to the consumers.