CONTROL AND SETTING PANEL

Setting up and starting Presscontrol Wall Pro is an extremely easy and intuitive 
operation thanks to the large and bright display that shows the information and the 
keyboard that allows you to enter and modify the pump operating parameters rapidly.

DISPLAY

KEYBOARD

SIGNALING

Serial number and data matrix of the device

The indicator LEDs of the main phases of operation of the device remain visible even when the display goes out to allow 
the user to have the status of the system under control at all times.

Note: The Service Light does not preclude the system from operating. On the display, a description of the required action  
           will be displayed (e.g. recharging the pressure tank).

Data transmission with NFC technology. 
Place mobile phone close to the icon for information transfer.

Device energized

Pump running

VFD On/Off

Communication between devices is active

Request for maintenance

Failure

The figure shows an example of displaying information divided into 4 quadrants:

1 - Pump status
3 - VFD operating frequency

2 - Real system pressure
4 - Current absorbed in Amperes

To save energy, the display will turn off one minute after the last action. To turn the 
display on again, simply press any button on the keyboard.

ON/OFF BUTTON 

Starts and stops the pump

ESC BUTTON

To exit the programming screen

OK BUTTON

To access programming and confirm data entry

RESTART BUTTON

For manual resetting in the event of a fault

UP ARROW 

Menu scroll upwards

RIGHT ARROW 

Menu scrolling to the right and to increase parameter values

DOWN ARROW 

Menu scrolling downwards

LEFT ARROW 

Menu scrolling to the left and to decrease parameter values

Summary of Contents for PRESSCONTROL WALL PRO T9

Page 1: ...he restart pump pressure Stops the pump in case of water shortage and protects it from dry running Is equipped with automatic restart in case of failure and anti jamming function Can be installed on surface and submersible pumps Ensures energy saving Can be installed on surface pumps and submersible pumps Supplied with a 16 bar pressure sensor Standardly equipped with a communication interface to ...

Page 2: ...ion with NFC technology Place mobile phone close to the icon for information transfer Device energized Pump running VFD On Off Communication between devices is active Request for maintenance Failure The figure shows an example of displaying information divided into 4 quadrants 1 Pump status 3 VFD operating frequency 2 Real system pressure 4 Current absorbed in Amperes To save energy the display wi...

Page 3: ...h different supply voltages AUTOMATIC RESTART AND ANTI JAMMING FUNCTION In case of stopping due to a water shortage the devices will automatically make 10 double attempts to rearm over the 24 hours following the failure each lasting approximately 5 seconds to allow the pumps and the system to reload if possible The user can try to rearm the devices at any time by pressing the Restart button If for...

Page 4: ...stem as a Slave device INSTALLATION AND SETUP OPERATION Connect the devices together using the serial port Program the Presscontrol Wall PRO selected as Master following the instructions on the display Enable communication on the Master Presscontrol Wall PRO that automatically will transfer the data to the other connected Presscontrol Wall PRO units that will act as Slave devices You can now start...

Page 5: ...time the pumps stop it will be the second third and or fourth pump to startup first until finally returning to the first one and so on The alternation of start up and operation of the pumps that make up the pressure set guarantees a uniform wear therefore longer life of the pressure set In case of stopping due to a water shortage the devices will automatically make 10 double attempts to rearm over...

Page 6: ...s Digital ammeter Yes Yes Yes Yes Yes Dry running protection Yes Yes Yes Yes Yes Automatic restart Yes Yes Yes Yes Yes Anti jamming function Yes Yes Yes Yes Yes Protection fuse Yes Yes Yes Yes Yes Short circuit protection between phases Yes Yes Yes Yes Yes Short circuit protection between phases and earth Yes Yes Yes Yes Yes Amperometric protection Yes Yes Yes Yes Yes Voltage surge protection Yes ...

Reviews: