OPERATING THE CHLORINE GENERATOR
This process begins after the chlorine generator is assembled. It is assumed you have
a water tank or cistern containing water you wish to chlorinate. It also assumes that
you have a means to dispense the water from the tank after it is treated.
8
WaterStep M-100 Chlorine Generator
BEFORE OPERATING THE UNIT
1. Make sure drain tubes (red and black)
at the bottom of the unit are clamped
closed by the pinch clamps.
2. The 1” plug on the fill tube should be
hand tight.
Do not overtighten!
Tape
threads on plug, as needed.
3. Confirm the air hole on the chlorine
side is unobstructed and open to the
atmosphere.
4. Make sure you have a fully charged
12-volt DC battery.
• Place about 400ml of water into the
empty water bottle.
• Using the metal measuring cup, place
1-1/2 measures of table salt into the
water bottle (this will be about 125
grams or 4.5 oz. of salt). If rock salt
is used, first pound it to small particles
before mixing it with water.
• Place cap on water bottle and shake
the mixture to allow the salt to
completely dissolve.
CHLORINATION PROCESS
• Remove the
1” plug from
the fill tube.