Designation model alfea extensa duo +
5
6
8
10
Nominal heating performances
(outdoor temperature/ initial temperature)
Heat output
+7 °C / +35 °C - Floor heating system
kW
4,50
6,00
7,50
10,00
-7 °C / +35 °C - Floor heating system
kW
4,10
4,60
5,70
7,40
+7 °C / +45 °C - Low temperature radiator
kW
4,50
5,10
6,20
8,27
-7 °C / +45 °C - Low temperature radiator
kW
4,10
4,45
5,05
7,40
+7 °C / +55 °C - Radiator
kW
4,50
4,50
5,0
7,00
-7 °C / +55 °C - Radiator
kW
3,70
3,85
5,20
7,00
Power absorbed
+7 °C / +35 °C - Floor heating system
kW
1,00
1,41
1,84
2,49
-7 °C / +35 °C - Floor heating system
kW
1,47
1,74
2,23
2,97
+7 °C / +45 °C - Low temperature radiator
kW
1,31
1,50
1,87
2,53
-7 °C / +45 °C - Low temperature radiator
kW
1,86
2,04
2,47
3,70
+7 °C / +55 °C - Radiator
kW
1,79
1,79
1,94
2,86
-7 °C / +55 °C - Radiator
kW
2,20
2,33
3,34
4,15
Coefficient of performance (COP) (+7 °C / + 35 °C)
4,52
4,26
4,08
4,02
Electrical characteristics
Supply voltage (50 HZ)
V
230
Maximum current for appliance
A
11
12,5
17,5
18,5
Nominal current
A
4,5
6,3
8,1
10,9
Maximum current of the Heating electrical back-ups
A
13,05 / 26,1
Power of the Heating electrical back-ups (option)
kW
ajustable 3 or 6 kW
Real power absorbed by the fan
W
49
49
49
100
Real power absorbed by the circulation pump
W
24
Maximum power absorption by the outdoor unit
W
2530
2875
4025
4255
Electrical back-up power DHW
W
1500
Hydraulic circuit
Maximum operating pressure Heating
bar
3
Maximum operating pressure Domestic hot water tank
bar
10
Hydraulic system flow rate 4°C<Δt<8°C (nominal conditions)
l/h
490 / 980
650 / 1300
810 / 1620
1080 / 2160
Various
Weight of outdoor unit
kg
41
41
42
60
Weight of hydraulic unit (empty / full of water)
kg
152 / 366
Water capacity of the hydraulic unit / of the domestic tank
l
24 / 190
Noise level at 1 m
1
(hydraulic unit)
dB
39
Sound power level according to EN 12102
2
(hydraulic unit)
dB
46
Noise level at 1 m
1
(outdoor unit)
dB
38
38
41
42
Sound power level according to EN 12102
2
(outdoor unit)
dB
63
63
69
69
Heating system operating limits
Outdoor temperature mini / maxi
°C
-20 / +35
Initial max. heating water temperature Floor heating system
°C
45
Initial max. heating water temperature Low temperature radiator
°C
52
Refrigeration circuit
Diameter of "Gas" pipes
inches
1/2
1/2
5/8
5/8
Diameter of "Liquid" pipes
inches
1/4
1/4
1/4
3/8
Factory charge of refrigerant R410A
3
g
1100
1100
1400
1800
Maximum operating pressure
bar
41,5
Minimum / Maximum length of pipes
4
m
5 / see
"Additional charge", page 22
Maximum length of pipes
5
/
Maximum level difference
m
20 / 15
1 .3
Specifications
1
Sound pressure level in (x)m of the device, 1,5m of the ground,
the open field.
2
The sound power level is a laboratory measure of the emitted
sound power but contrary to the noise level, it doesn't correspond to
the measure of the felt.
3
Refrigerant R410A (as per the standard EN 378.1).
4
Factory charge of refrigerant R410A.
5
Taking into account the possible additional load of refrigeration fluid
R410A (see
"Additional charge", page 22).
Installation and operating manual "1585 - EN"
- 5 -
Air to Water Heat Pump (Split integrated DHW type)
Designation model Waterstage Comfort
5
6
8
10