10 Quick-start procedure
Before switching on the hydraulic unit:
• Check the electric wiring.
• Check the refrigeration circuit and make sure the gas
supply has been performed.
• Check the pressure of the hydraulic circuit (1-2 bar),
check that the heat pump is purged, and the rest of the
installation.
• Make sure that ALL DIP SW are OFF before starting
up
10 .1 Start-up check-list
10 .1 .1 Before starting-up
•
Sight checks
Outdoor unit (see chapiter
"Installation of the outdoor unit", page 13
).
OK
Non compliant
Location and fittings, condensate evacuation.
Compliance with distances from obstacles.
•
Hydraulic checks
Hydraulic unit (see chapiter
"Installing the hydraulic unit", page 15
).
OK
Non compliant
Value
Connection of pipes, valves and pumps (1 or 2 circuits, DHW).
Installation water volume (expansion vessel of adequate capacity ?).
No leaks.
Main system pressure and degassing (0,3bar > expansion vessel pre-loading).
•
Refrigeration connections and checks
(see chapiters
"Refrigeration connections", page 16
and
"Filling the installation with gas", page 20
).
OK
Non compliant
Refrigerant circuits control (Sealing respected, no dust and moisture)
Connections between units (pipe length, flare tightening torque...).
Installation of HP, LP pressure switches on "Gas" line (large pipe).
Pump down required.
Nitrogen leak test (~ 10 bar).
Opening of refrigeration valves to outdoor unit.
Refrigerant filling of hydraulic unit and pipes.
•
Electrical checks
Outdoor unit (see chapiter
"Electrical connections", page 30
).
OK
Non compliant
Value
Main power supply 230v.
Protection by rated circuit breaker.
Cable cross-section.
Earth connection.
Hydraulic unit (see chapiter
"Electrical connections
on the hydraulic unit side", page 33
).
OK
Non compliant
Connection with outdoor unit (phase, neutral, earth).
Sensors connection (positioning and connections).
3 way valve and circulators connections.
Power supply and protection of electric auxiliary (option).