Problem 

Possible Causes 

Possible Solutions 

Pump does not start 

1.

 

No power or cord not 
connected. 

2.

 

Float switch is down 
or in the ‘off’ position. 

1.

 

Check outlet power or 
plug in pump 

2.

 

Adjust float switch to 
‘on’ position 

No flow 

1.

 

Inlet is clogged 

2.

 

Outlet hose is bent or 
clogged 

1.

 

Clean inlet 

2.

 

Reset hose and clear 
debris 

Pump does not 

switch off 

1.

 

Float cannot sink or 

move to off position 

1.

 

Adjust pump and float, 

then retest 
functionality 

Insufficient flow 

1.

 

Inlet clogged 

2.

 

Reduced pumping 
capacity by dirty or 

abrasive water 

1.

 

Clean inlet 

2.

 

Clean pump and flush 
with clean water 

Pump switches off 
after short operating 

period 

1.

 

Thermal protection 
stops pump due to 

dirty water 

2.

 

Water too hot and 
thermal protection 

stops pump 

1.

 

Unplug and clean 
pump 

2.

 

Use water below 82°F 

 

TROUBLESHOOTING 

Summary of Contents for HydraPump Submersible

Page 1: ...Copyright Watershed Innovations All rights reserved HydraPump Documentation Rev 2 0 HydraPump Submersible Owner s Guide...

Page 2: ...TO PERSONS before using the pump Absorbent cloth or HydraTowel for clean up and maintenance Standard hoses for the outlet PTFE tape sometimes this is referred to as plumber s tape o This item is recom...

Page 3: ...K OR INJURY TO PERSONS SAVE THESE INSTRUCTIONS WARNING When using electrical pumps basic precautions should always be followed including the following 1 Read all instructions before using the pump 2 T...

Page 4: ...n be cut off for installations requiring the 1 NPT connector The NPT threads can also be removed and a hose clamped to the remaining connector Finally the entire hose adapter can be unscrewed and a 1...

Page 5: ...electric shock This pump is equipped with a cord that is a grounded plug The plug must be plugged into an appropriate GFCI outlet that is properly installed and grounded in accordance with all local...

Page 6: ...e b After the float has been set always test to make sure that the desired operation is being achieved OPERATING Once the pump is installed it only needs to be plugged in to operate The pump should no...

Page 7: ...ose is bent or clogged 1 Clean inlet 2 Reset hose and clear debris Pump does not switch off 1 Float cannot sink or move to off position 1 Adjust pump and float then retest functionality Insufficient f...

Page 8: ...ump is still resting in water and not mud Excess debris will need to be removed from the pit before the pump is installed for long term operation All fibrous particles and debris that have built up in...

Page 9: ...tor HP Copper Wound single phase Power Supply 115 60Hz 8 4A Max Pumping Rate 3000 GPH Max Delivery Height 30 ft Max immersion Depth 23 ft Max Water Temperature 82 F See chart below for flow versus hei...

Reviews: