Watershed Innovations HydraPump Submersible Owner'S Manual Download Page 3

 

©Copyright Watershed Innovations. All rights reserved. 

 

 

HydraPump Documentation Rev 2.0 

 

 

Make sure your work area where you intend to use the pump is clear of clutter and 
is well lit. Never operate a submersible pump in a pool when people are in the pool.  
 

The pump is designed to pump water and has only been tested for that purpose. The 
pump can be used with clean and dirty water but the cleaner the water the better 

the pump will operate. Lastly, please note that the pump will only pump water down 
to a level of approximately 1”. 
 

 

 

INSTRUCTIONS PERTAINING TO THE RISK OF FIRE, ELECTRIC SHOCK OR 

INJURY TO PERSONS. SAVE THESE INSTRUCTIONS. 

 

WARNING – When using electrical pumps, basic precautions should always be 
followed, including the following:

 

1.

 

Read all instructions before using the pump. 

2.

 

To reduce the risk of injury or improper operation, close supervision and 
thorough setup verification is recommended for safe pump operation. 

3.

 

Do not put fingers or hands into a water pump inlet our outlet when 
operating.  

4.

 

Unplug the power before attempting to move or service the pump. 

5.

 

Do not let the electrical connection come in contact with water. 

6.

 

For proper grounding instructions see the ELECTRICAL CONNECTION 
portion of this manual. 

7.

 

If you are unsure of any of these instructions please contact a professional for 
assistance. 

 

 

SITE PREPARATION 

IMPORTANT SAFETY INSTRUCTIONS 

Summary of Contents for HydraPump Submersible

Page 1: ...Copyright Watershed Innovations All rights reserved HydraPump Documentation Rev 2 0 HydraPump Submersible Owner s Guide...

Page 2: ...TO PERSONS before using the pump Absorbent cloth or HydraTowel for clean up and maintenance Standard hoses for the outlet PTFE tape sometimes this is referred to as plumber s tape o This item is recom...

Page 3: ...K OR INJURY TO PERSONS SAVE THESE INSTRUCTIONS WARNING When using electrical pumps basic precautions should always be followed including the following 1 Read all instructions before using the pump 2 T...

Page 4: ...n be cut off for installations requiring the 1 NPT connector The NPT threads can also be removed and a hose clamped to the remaining connector Finally the entire hose adapter can be unscrewed and a 1...

Page 5: ...electric shock This pump is equipped with a cord that is a grounded plug The plug must be plugged into an appropriate GFCI outlet that is properly installed and grounded in accordance with all local...

Page 6: ...e b After the float has been set always test to make sure that the desired operation is being achieved OPERATING Once the pump is installed it only needs to be plugged in to operate The pump should no...

Page 7: ...ose is bent or clogged 1 Clean inlet 2 Reset hose and clear debris Pump does not switch off 1 Float cannot sink or move to off position 1 Adjust pump and float then retest functionality Insufficient f...

Page 8: ...ump is still resting in water and not mud Excess debris will need to be removed from the pit before the pump is installed for long term operation All fibrous particles and debris that have built up in...

Page 9: ...tor HP Copper Wound single phase Power Supply 115 60Hz 8 4A Max Pumping Rate 3000 GPH Max Delivery Height 30 ft Max immersion Depth 23 ft Max Water Temperature 82 F See chart below for flow versus hei...