56
|
90
Safety Introduction Product Overview
Removing the Cover
1. Remove the 3 screws and washers that are used to secure the cover to the
frame and set them aside (
).
1
3
2
1. Screw
2. Washer
3. Cover
Figure 47
2. Remove the cover and set it aside.
Connecting the Power Supply
Disconnect the power
before servicing the pump.
Current can cause serious
injury or death.
High Current
•
•
Read and understand the following statements before continuing:
• The pump motor uses 30 A to 100 A of current to operate.
• Electrical current is dangerous and can cause serious injury or death.
• Do not attempt to connect the pump motor to the power source if you
have not been trained and understand the safety practices needed to
install devices requiring 30 A to 100 A to operate.
Ensure the power source used meets the following specifications:
Model
Voltage
Amps
AQUIS 1.5
12 Vdc
50 A
24 Vdc
30 A
AQUIS 3.0
12 Vdc
80 A
24 Vdc
50 A
AQUIS 6.0
12 Vdc
100 A
24 Vdc
80 A