16. FAULT FINDING
A
PUMP DOES NOT RUN
1.
Check mains wired correctly and switched on – fuse 3 Amps correct and operable.
2.
Check electrical connections.
B
WATER DOES NOT FLOW
1.
Check that all supply valves (including isolating valves) are turned on.
2.
Check cold and hot water are connected to the correct inlet control valve.
C
PUMP STOPS – water flow reduces
1.
An automatic anti-scald system is fitted. If, for any reason, the shower water
temperature star ts to exceed the scald temperature, the pump will be switched
of f, until the water temperature is corrected.
To correct, adjust temperature control knob clockwise to reduce shower water
temperature.
2.
The motor is fitted with a thermal cutout. Should the pump be run for an
excessive period, it will cut out. When the motor cools it will self-reset.
D
POOR WATER FLOW
Clean handset spray plate.
E
CUSTOMER SERVICE HELPLINE
For advice during installation or assistance with any problems,
contact the Customer Service Helpline on: 01883 730339.
WATERMILL PRODUCTS LTD
FAIRVIEW INDUSTRIAL ESTATE, HOLLAND ROAD, HURST GREEN, OXTED, SURREY, ENGLAND RH8 9BD
TEL: 01883 715425 FAX: 01883 716422
e-mail: [email protected] website: www.watermill-showers.co.uk
Printed in England
CUSTOMER SERVICE HELPLINE: 01883 730339
17. TECHNICAL DATA
l
Mains Voltage Types
Low Voltage Types
ELECTRICAL
Volts/Phase/Frequency
230/1/50
Transformer Input
230/1/50
Transformer Output
32/1/50
Current
0.8A
0.85A (TX Primar y)
Power Consumption
130W
165W
Rating
20 min on 60 min of f
20 min on 60 min of f
Motor
Universal
Universal
MECHANICAL
Inlet Head (min-max)
1-10m
1-10m
Max Developed Pump Head
14m
13m
Max Working Pressure
2.5bar
2.5bar
DIMENSIONS
Width
265
265
Height
225
225
Depth Sur face Mounted
97
97
Depth Recessed
57
57