background image

 INSTALLATION & USER INSTRUCTIONS

Thank you for purchasing this Whale® product. 

For over 70 years Whale has led the way in the design and manufacture of freshwater, bilge and waste management systems including plumbing, taps, showers and 

pumps, for low voltage applications. The company and its products have built a reputation for quality, reliability and innovation backed up by excellent customer service. 

For information on our full product range visit: 

www.whalepumps.com

Grey Waste Tank - Service Kits

The Grey Waste Tank enables the user to manage all grey waste on board easily, through one skin fitting. The Intelligent Control sensor integrated into the tank lid 

provides automatic operation of the grey waste pump. The sensor will detect water in the grey waste tank at a pre-determined level, and will automatically activate the 

grey waste pump. When the tank is emptied, the switch will automatically turn the grey waste pump off. The 2 sensor models include a second sensor which can be 

used to control a second grey waste pump. It is factory set to activate at a higher water level and will provide additional pumping capacity during periods of high inflow to 

the grey waste tank. Alternatively, the second sensor can be wired to a high level alarm, warning of a high water level within the grey waste tank. 

Read the following carefully before installation.

WARNING:

 Please note that incorrect installation may invalidate warranty.

To the Fitter: 

Check that the product is suitable for the intended application, follow these installation instructions and ensure all relevant personnel read the points listed below. Also 

ensure that these operating instructions are passed on to the end user. The manufacturer cannot be held responsible for claims arising from incorrect installation, 

unauthorised modification or misuse of the product.

To the User: 

Read the following instructions carefully.

The Grey Waste Tank is designed to collect grey shower waste water. If it is intended for use for any other purpose or with any other liquid, it is the user’s responsibility 

to ensure that the tank and switch are suitable for the intended use and, in particular, that the materials are fully compatible with the liquids to be used. The integrated 

Intelligent Control sensor is designed to operate at 12V d.c or 24V d.c. only. The sensor is suitable for use with pumps operating with current up to 20A, and is 

recommended for use with Whale Gulper® 220 or Gulper® 320 grey waste pumps (see www.whalepumps.com/marine for information).

• With all applications, it is important that a system of safe working practice is applied to installation, use and maintenance. Ensure the electric supply is turned off and  

  that the waste water system is drained before installation.

• The Grey Waste Tank is designed for the storage of grey waste water in recreational marine vessels. Your warranty may be invalidated if the product is used  

  in other applications or outside the remit of the standards quoted on the packaging/product literature. 

• 

WARNING:

 Installation 

must

 be carried out by a qualified electrician. Improper wiring can cause a fire resulting in injury or death. Suggested wiring information (Figure

  1A and Figure 1B) is given as a guide only, and wiring 

must 

comply in accordance with the applicable electrical standards. Appropriate size fuses or circuit breakers

  

must 

be installed.

• Do not shorten the wires.

Contact Whale S44 (0)28 9127 0531 for specific advice on your installation.

AK1005 / AK1006 / AK1007 / AK1008

 1. 

 SPECIFICATION

 2. 

PRINCIPLES OF OPERATION

 3. 

TO THE FITTER & TO THE USER

 4. 

APPLICATION

 5. 

WARNINGS

Model

Grey Waste Tank - Service Kits

Product 

Codes

AK1005

AK1006

AK1007

AK1008

No. of Sensors

1

2

Voltage

12V d.c. / 24V d.c.

Electrical 

Connections

Tinned wire ends

1 x Deutsch

DT06-3S-P012

2 x Deutsch

DT06-3S-P012

Tinned wire ends

Materials

Seals: EPDM/Neoprene, Monprene®

Lid: Glass Filled Polypropylene, ABS, Polyurethane 

Grey Waste Tank with Integrated Intelligent Control - Service Kits

Pump Model

Recommended Automotive Fuse 

Size (Amps)

Gulper 220 (12V dc)

5

Gulper 220 (24V dc)

2.5

Gulper 320 (12V dc)

10

Gulper 320 (24V dc)

5

Gulper IC (12V dc)

10

Gulper IC (24V dc)

5

1

Summary of Contents for AK1005

Page 1: ...ed for use for any other purpose or with any other liquid it is the user s responsibility to ensure that the tank and switch are suitable for the intended use and in particular that the materials are...

Page 2: ...eaned from debris residue regularly at least every 3 months See Figure 3 Do not use an abrasive cleaner Figure 3 Cleaning Maintenance The lid is not a serviceable part The yellow cover must not be rem...

Page 3: ...opyright Whale 2019 All rights reserved All rights reserved Reproduction in whole or in part without permission is prohibited WHALE is a registered trademark of Munster Simms Engineering Limited Bango...

Page 4: ...wassers Falls er f r einen anderen Verwendungszweck oder mit anderen Fl ssigkeiten verwendet werden soll hat der Nutzer eigenverantwortlich sicherzustellen dass Tank und Schalter f r den vorgesehen Ve...

Page 5: ...ZAHL 1 Grauwasserdeckel mit integriertem n Sensor en 7 MONTAGEANWEISUNGEN Lampe oder Alarm Abbildung 1A Anschlussschema f r Modelle mit einem Sensor Abbildung 1B Anschlussschema f r Modelle mit zwei S...

Page 6: ...ne Genehmigung weder ganz noch teilweise vervielf ltigt werden Whale ist ein eingetragenes Warenzeichen von Munster Simms Engineering Ltd in Bangor Nordirland Das Unternehmen handelt auch unter dem Na...

Page 7: ...es provenant de la douche S il est pr vu de l utiliser d autres fins ou avec d autres liquides l utilisateur est responsable de s assurer que le collecteur et l interrupteur correspondent l usage pr v...

Page 8: ...les principaux du capteur Connecter la pompe eaux us es C bles secondaires du capteur Connecter l alarme de niveau lev ou la pompe eaux us es secondaire C blage Figure 1A ou figure 1B Pour AK1006 et A...

Page 9: ...egistr e de Munster Simms Engineering Limited Bangor Irlande du Nord active sous le nom de Whale La philosophie de Whale consiste am liorer en permanence nos produits et nous nous r servons le droit d...

Page 10: ...i scarico grigie provenienti dalla doccia Se destinato all uso per qualsiasi altro scopo o con qualsiasi altro liquido responsabilit dell utilizzatore assicurare che il pozzetto di raccolta e l interr...

Page 11: ...mpa funzioni e che le acque grigie siano rimosse dal pozzetto di raccolta Nota bene in caso di utilizzo di una valvola di mare accertare che sia aperta prima dell uso Fusibile Fusibile Fusibile Interr...

Page 12: ...ostro consenso WHALE un marchio registrato di Munster Simms Engineering Limited Bangor Northern Ireland operante come Whale La politica di Whale quella di apportare continui miglioramenti e quindi ci...

Page 13: ...ises de las duchas Si est prevista su utilizaci n para cualquier otra finalidad o para cualquier otro l quido ser responsabilidad del usuario garantizar que el dep sito y el conmutador sean adecuados...

Page 14: ...r primario Conectar a bomba de aguas residuales grises Conductores de sensor secundario Conectar a alarma de alto nivel o a bomba secund Cableado V anse las Figuras 1A u 1B Para AK1006 y AK1007 vea ta...

Page 15: ...tal o parcial sin permiso WHALE es una marca registrada de Munster Simms Engineering Limited Bangor Irlanda del Norte comerciada como Whale La pol tica de Whale est en continua mejora por lo que nos r...

Page 16: ...m den skall anv ndas i annat syfte eller med annan v tska r det anv ndarens ansvar att se till att tanken och brytaren passar till den avsedda anv ndningen och I synnerhet att materialen r helt kompat...

Page 17: ...attnet fr n tanken OBS om en bottenf rskruvning anv nds se till att den r ppen f re anv ndningen Manuellt Manuellt Till brun ledning f r sekund r sensor Till brun vitrandig ledning f r sekund rsensor...

Page 18: ...rdande av begr nsad garanti Copyright Whale 2019 Med ensamr tt M ngfaldigande helt eller delvis utan tillst nd r f rbjudet WHALE r ett registrerat varum rke tillh rande Munster Simms Engineering Limi...

Page 19: ...k ytt johonkin muuhun tarkoitukseen tai muiden nesteiden kanssa k ytt j vastaa siit ett s ili ja kytkin soveltuvat aiottuun k ytt n erityisesti ett materiaali on t ydellisen yhteensopiva k ytett vien...

Page 20: ...a j tevesi poistuu s ili st Huomaa Pohjaventtiili k ytett ess varmista ett se on auki Musta johto Musta johto Punainen johto Punainen johto Pois Pois Akku Akku Autom Autom P anturin ruskeaan P anturin...

Page 21: ...2019 Kaikki oikeudet pid tet n Kopiointi kokonaan tai osittain ilman lupaa on kielletty WHALE on Munster Simms Engineering Limited Bangor Northern Ireland kauppanimi Whale rekister im tuotemerkki Wha...

Page 22: ...Engineering Ltd 2 Enterprise Road Bangor Co Down N Ireland BT19 7TA Tel 44 0 28 9127 0531 Email info whalepumps com USA Tel 1 616 897 9241 Email usasales whalepumps com www whalepumps com Ref 181 347_...

Reviews: