10. FAULT FINDING

If the pump doesn’t start, check the following.

1.

Electricity supply and fuse (5 Amps rating)

2.

Are isolating valves turned on?

3.

Has pump run for a long time, causing thermal protection to turn off motor? Wait at

least 2 hours for cut-out to automatically reset.
4.

Sufficient water flow to operate the flow switches (0.5 litres per minute) or

approximately 10 inches head of water?
5.

Pump filters blocked – this can cause insufficient flow to pump – drain down hot and

cold water supply pipes, clean or replace filters as necessary.
6.

Is pump correctly installed with outlets (flowswitches) vertical?

Pump won’t turn of f

1.

Is shower mixer valve fully off?

2.

Is air entrapped in the shower system?

3.

Is flow switch locked in the up (on) position with dirt or some other foreign matter?

Unstable water temperature/noisy pump?

A common cause of poor shower performance and control is air entering the pump, most
commonly from the hot water cylinder.

Air will cause erratic operation of the pump, noise and unstable shower water

temperature.

To reduce the effects of air in the hot water supply:

1.

Reduce hot water temperature to 60˚C.

2.

Ensure adequate feed to the pump. There should be at least a 2 metre lead (measured

from cold storage water level to input of pump) and all pump supply pipes should be with
22mm 

gate

valves.

3.

Fit

Surrey flange

to ensure good air separation at hot water cylinder.

4.

The hot water supply pipes should not have any high sections allowing air traps. If

necessary re-plumb hot water supply pipe, keeping as direct and short as possible.
5.

If it is not possible to control the temperature of the hot water a thermostatic blend

valve should be installed. The hot water feed from the cylinder to the pump is disconnected.
The blend valve is connected to both the hot water and cold water supply with the output
connected as the hot water feed to the pump. The thermostatic blend valve can then be
adjusted to ensure the correct 60˚C temperature.

Note: All plumbing work should conform to Water Supply (Water Fittings) Regulations
1999.

In this event turn off service valves, disconnect final connection to the pump, clean

filter, reconnect, turn on water supply.
3.

The flexible pump hoses can, dependent on water temperature and mechanical stress,

deteriorate with age. We recommend that all flexible hoses and connections are inspected at
least every 6 months. Replace as necessary to prevent leaks.

5

Summary of Contents for ANHPC60DLV

Page 1: ...INSTALLATION INSTRUCTIONS LOW VOLTAGE SHOWER PUMPS Models PC25DLV PC50DLV PC55SLV PC70DLV ANHPC60DLV CUSTOMER SERVICE HELPLINE 01883 730339 Performance Shower Products...

Page 2: ...ollow the appropriate sections PAGE 1 GENERAL 1 2 IMPORTANT INSTRUCTIONS 1 3 POSITIONING PUMP 1 4 HOT WATER CYLINDER CONNECTIONS 3 5 COLD WATER SUPPLY 3 6 CONNECTING PUMP 3 7 ELECTRICAL CONNECTIONS 4...

Page 3: ...2 metres If the pump is to be installed in the loft the height from the top of the water in the cold water storage tank must be at least 2 metres above the inlet to the pump 4 Do not use any jointing...

Page 4: ...n the cold water storage cistern and the outlet of the shower handset of 250mm 10 See Fig 1 Negative Head If the water level of the cold water storage cistern is below the level of the shower outlet t...

Page 5: ...has been pumped for the first time Ensure filters are fitted to the inlets and washers to outlets 6 CONNECTING PUMP 4 HOT WATER CYLINDER CONNECTIONS DO NOT USE ANY JOINTING COMPOUNDS The use of a Sur...

Page 6: ...should have supplementary earth bonding Where the earth continuity has been broken by flexible pipes the pump discharge and suction pipework should be connected with earthing clamps to BS951 and 4mm...

Page 7: ...ter temperature to 60 C 2 Ensure adequate feed to the pump There should be at least a 2 metre lead measured from cold storage water level to input of pump and all pump supply pipes should be with 22mm...

Page 8: ...ly head of at least 2 metres 6 ft That is the level of the water in the tank must be this distance above the pump 3 a Do not use any jointing compounds these compounds will cause seals to leak b If so...

Page 9: ...7...

Page 10: ...3m 17m 20m Max Working Pressure 3 bar 3 bar 3 bar 3 bar Approx Starting Flow Rate 0 5lpm 0 5lpm 0 5lpm 0 5lpm DIMENSIONS Length mm 275 275 225 285 Width mm 120 120 120 120 Height mm 185 185 185 185 NO...

Page 11: ...s of purchase accompanied by a copy of the original invoice proof of purchase We will acknowledge receipt of the guarantee registration card within ten days It is this guarantee acknowledgement that a...

Page 12: ...ot suitable for the application It helps us to help you if we can obtain details of the application It is also very useful to have digital photographs of the installation e mailed to service watermill...

Reviews: