Watermill ANHPC60DLV Installation Instructions Manual Download Page 10

11. TECHNICAL DATA

PC25DLV

PC50DLV

PC55SLV

PC70DLV

ELECTRICAL

Transformer Input

230V/50Hz

230V/50Hz

230V/50Hz

230V/50Hz

Transformer Output

31V

34V

38V

40V

Power Consumption

150W

220W

110W

380W

Rating

S2 25min

S1 Continuous

S2 75min

S1 Continuous

Motor

Permanent Magnet Low Voltage dc

MECHANICAL

Inlet Head (min-max)

2-10m

2-10m

2-10m

2-10m

Max Developed Pump Head

8m

13m

17m

20m

Max Working Pressure

3 bar

3 bar

3 bar

3 bar

Approx. Starting Flow Rate

0.5lpm

0.5lpm

0.5lpm

0.5lpm

DIMENSIONS

Length (mm)

275

275

225

285

Width (mm)

120

120

120

120

Height (mm)

185

185

185

185

NOISE

The sound pressure level 1m from the pump is less than 70dbA

For ANHPC60DLV See supplementary instructions

8

WATERMILL PRODUCTS LTD

WATERMILL HOUSE, FAIRVIEW INDUSTRIAL ESTATE, HOLLAND ROAD, HURST GREEN, OXTED, SURREY RH8 9BD

CUSTOMER SERVICE HELPLINE TEL: 01883 730339

Email: [email protected]  web: www.watermillshowers.co.uk

ML 305 02/04

Printed in England

Summary of Contents for ANHPC60DLV

Page 1: ...INSTALLATION INSTRUCTIONS LOW VOLTAGE SHOWER PUMPS Models PC25DLV PC50DLV PC55SLV PC70DLV ANHPC60DLV CUSTOMER SERVICE HELPLINE 01883 730339 Performance Shower Products...

Page 2: ...ollow the appropriate sections PAGE 1 GENERAL 1 2 IMPORTANT INSTRUCTIONS 1 3 POSITIONING PUMP 1 4 HOT WATER CYLINDER CONNECTIONS 3 5 COLD WATER SUPPLY 3 6 CONNECTING PUMP 3 7 ELECTRICAL CONNECTIONS 4...

Page 3: ...2 metres If the pump is to be installed in the loft the height from the top of the water in the cold water storage tank must be at least 2 metres above the inlet to the pump 4 Do not use any jointing...

Page 4: ...n the cold water storage cistern and the outlet of the shower handset of 250mm 10 See Fig 1 Negative Head If the water level of the cold water storage cistern is below the level of the shower outlet t...

Page 5: ...has been pumped for the first time Ensure filters are fitted to the inlets and washers to outlets 6 CONNECTING PUMP 4 HOT WATER CYLINDER CONNECTIONS DO NOT USE ANY JOINTING COMPOUNDS The use of a Sur...

Page 6: ...should have supplementary earth bonding Where the earth continuity has been broken by flexible pipes the pump discharge and suction pipework should be connected with earthing clamps to BS951 and 4mm...

Page 7: ...ter temperature to 60 C 2 Ensure adequate feed to the pump There should be at least a 2 metre lead measured from cold storage water level to input of pump and all pump supply pipes should be with 22mm...

Page 8: ...ly head of at least 2 metres 6 ft That is the level of the water in the tank must be this distance above the pump 3 a Do not use any jointing compounds these compounds will cause seals to leak b If so...

Page 9: ...7...

Page 10: ...3m 17m 20m Max Working Pressure 3 bar 3 bar 3 bar 3 bar Approx Starting Flow Rate 0 5lpm 0 5lpm 0 5lpm 0 5lpm DIMENSIONS Length mm 275 275 225 285 Width mm 120 120 120 120 Height mm 185 185 185 185 NO...

Page 11: ...s of purchase accompanied by a copy of the original invoice proof of purchase We will acknowledge receipt of the guarantee registration card within ten days It is this guarantee acknowledgement that a...

Page 12: ...ot suitable for the application It helps us to help you if we can obtain details of the application It is also very useful to have digital photographs of the installation e mailed to service watermill...

Reviews: