1. No Cold Water Flowing: There are a number of reasons that could be causing this 

problem. 1) Check if the water in the building is turned off! 2) Check if the isolating 

valve has been turned off! 3) Check if the filter blocked with sediments or passed 

its change date! 4) Check if the solenoid valves are operating! 5) Check if the cold 

tank has frozen. 6) Check if the red LED warning light is flashing!
2. Water Flows but is Not Cold: 1) Check that the compressor switch at the rear 

of  the  machine  is  turned  on.  2)  Have  you  just  taken  more  than  3  jugs  of  water? 

The machine takes about 30 min to recover temperature after heave use. 3) Is the 

machine sited in an area with an ambient room temperature in excess of 30°C. 4) 

Does the machine have a 5cm air gap around it? 5) Test the machine cooling system 

for loose of refrigeration gas. If the compressor is continually running hot and mot 

making  cold  water,  then  this  could  mean  it  need  gas.  Check  the  compressor  to 

ensure it is running. Make sure the thermostat is adjusted correctly.
3. Water has a Plastic or Funny Taste: 1) If the machine is new it may need to be 

flushed. 2) Has the machine been unused over a long weekend? Then flush 5 litres of 

water before using. 3) Fit a new filter if it has passed its changing date. 4) Contact you 

local dealer if adverse local water conditions are causing taste problems.
4. Restricted or Slow flow of cold or sparkling water: 1) Check that the water 

supply is above 1.5 bar or 21 PSI, as the machine will not function correctly below 

this! 2) Check that the gas bottle is not empty. 3) Check that the filter is not blocked 

or past its changing date. 4) Check that the faucet is not blocked.
5. Vend buttons sticking:

 

1) this fault is caused by dirt or cleaning material filling 

the gap around the button. Do not use cream or abrasive surface cleaner.

6. Red LED Warning Light flashing: 1) the pump has been running too long and 

has timed out. Please check the water supply to the pump. Te reset the pump turn 

the power on and off to the machine.
7. Machine no Power: 1) check that the machine switches are on the back of the 

machine. 2) Isolate the power supply and check the machine fuse. 3) Check that the 

power cord is plugged into the back of the machine and is pushed home. 4) Check 

that the power cord is plugged into the wall socket and is switched on. 5) Check that 

there is no problem with the building electrical supply.
8. No Hot Water: 1) Make sure the heater switch is on at the rear of the machine. 2) 

Does the hot tank need to be de-scaled? 3) Check the power supply to the heating 

element. 4) Disconnect the power and check the resistance of the heating element. 

5) Is the water supply to the machine turned on? 6) Are the solenoid valves operating 

correctly? 7) Is the filter blocked or past its change by date?
9. Factory sets the cold water at 5°C. Waterlogic strongly advice that you do not 

adjust the water to a colder temperature. Care should be taken if the thermostat is 

adjusted colder as this could increase the risk of the cold tank freezing. It is advised 

that any adjustment to the thermostat to male the water colder be done in small 

turns of the thermostat of a few degrees at a time. Allow the compressor to cycle on 

and off, check that the temperature is as required before any further adjustment. In 

the event that the cold tank should freeze then please turn the compressor switch 

mounted at the rear of the machine to the off position. Allow the machine to stand 

for one hour. Flush 1 litre of water through the machine, adjust the thermostat back 

to the factory position set point as marked and turn the compressor switch back on.

WL850 HV Technical Manual - Version 1, November 2007

26

27

Summary of Contents for WL850HV

Page 1: ...WL 850 HV Technical Manual...

Page 2: ...very Inspection Procedures PDI 14 Installation Procedures 16 Operating Instructions 20 Maintenance And Servicing 22 Sanitizing The Machine 24 Cleaning WL 850 HV 25 Troubleshooting The WL 850 HV 26 WL...

Page 3: ...uble cold tank assembly with choice of cold and sparkling and also a hot tank providing in total 5 5 litres of stored purified water The cold tank contains a specially designed ultra violet light that...

Page 4: ...teria growth UV LAMP The UV light is an 8watt germicidal lamp at a wavelength of 253 7 NM which is very efficient at destroying Bacteria found in water UV radiation kills Bacteria by destroying the DN...

Page 5: ...s FILTERS The filtration system on the WL850HV is NSF approved two stage filter Stage one is a 10 micron screen Stage two is a Granular Activated Carbon GAC process which will remove a whole range of...

Page 6: ...D WATER Understanding how it works Carbonated water is created by mixing carbon dioxide gas with water in a stainless steel chamber and is controlled by the following parameters 1 Temperature The cold...

Page 7: ...12 WL850 HV Technical Manual Version 1 November 2007 13 Components Layout Diagram Hot and Cold 1 14 15 16 17 3 4 5 6 7 8 9 10 11 12 13 2 29 28 27 26 30 31 32 33 34 18 19 20 21 22 23 24 25...

Page 8: ...in the off position and connect the unit to a power supply 5 Connect CO2 6 The unit is now live and suitable safety precautions should be taken 7 Flush water through the hot tank first until the water...

Page 9: ...the electrical supply to the machine Do not at this stage turn on these switches 8 The water temperature of the machine is factory set at 5 C for still cold water and 87 C for hot water Sparkling wate...

Page 10: ...se the cold tank to freeze If you need to increase the gas pressure then turn the screw adjuster clockwise on the gas regulator to do this and observe the needle position on the pressure indicator dia...

Page 11: ...dispense fresh water at your disposal 1 Green LED indicates the power is ON Flashing red LED indicates no water pump time out If LED flashes green then orange this indicates a UV fault 2 Push button...

Page 12: ...rtz sleeve Do not touch the UV lamp 10 Inspect the blue faucet nipple and if it is cracked or has Calcium build up replace it Please ensure that you use cleaning gloves when handling parts that come i...

Page 13: ...ple if so then replace it If the faucet nipple is OK then sterilise it and put back using clean rubber gloves 18 Remove and clean the drip tray and grill If the grill is damaged or heavily stained and...

Page 14: ...fault is caused by dirt or cleaning material filling the gap around the button Do not use cream or abrasive surface cleaner 6 Red LED Warning Light flashing 1 the pump has been running too long and h...

Page 15: ...ical Manual Version 1 November 2007 29 Exploded Diagram 50 32 37 33 34 36 30 35 22 39 40 41 42 43 44 31 10 12 14 13 15 24 25 27 28 29 45 11 46 47 23 26 48 18 38 19 21 20 16 17 9 6 7 8 1 4 3 2 5 Replac...

Page 16: ...ersion 1 November 2007 31 Wetted Parts Diagram 1 2 3 5 6 7 8 9 10 11 12 14 29 39 41 45 43 53 54 44 47 46 48 49 50 52 51 42 58 59 60 61 63 62 40 56 57 55 38 36 30 33 37 32 35 34 31 64 15 20 24 25 26 27...

Page 17: ...OLENOID VALVE FILTER DRYER HOT TANK COMPRESSOR CONDENSER FILTER IN Water SOLENOID VALVE WATER IN SPARKLING WATER OUT SOLENOID VALVE PUMP CHECK VALVE CO2 In SPARKLING TANK SAFETY VALVE COLD SENSOR COLD...

Page 18: ...lectrical Wiring Diagram Cold Ambient and Sparkling Electrical Wiring Diagram Cold Hot and Sparkling DANGER HIGH VOLTAGES PRESENT ON THIS PCB CARE MUST BE TAKEN WHEN LIVE TESTING DANGER HIGH VOLTAGES...

Page 19: ...W 34D 47H Water Connection Dia Dia Dia Dia Cold Water Temp 5 8 C 5 8 C 5 8 C 5 8 C Hot Water Temp 85 87 C 85 87 C 85 87 C 85 87 C Weight 40Kg 38Kg 29Kg 28Kg Power Supply 230Volt 50Hz 230Volt 50Hz 230V...

Page 20: ...Beacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 4141 N 156th Street Omaha NE 68116 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA Ca...

Reviews: