background image

 

WL7

 

FW 

Manual 

                                                                  Page 73 ‐ Revision:  6‐11‐2019

 

WL7 FW INSTALLATION PROCEDURES 

 

6.

 

Follow instructions on the screen.  The 

WL7 FW 

will instruct installer to hold the dispense button 

until a steady stream of water is flowing to the faucet.  This fills the Hot Tank. 

 

7.

 

The installer should then turn ON the Heater/Compressor (Green) Switch.    

 

8.

 

The 

WL7 FW

 

will now be in 

Operational Mode

 with both switches in the ON 

position and the home screen will appear on the display.  

 

9.

 

Dispense cold into container until steady stream of water is 

present to remove any trapped air from the circuit and repeat for the 
ambient (room temperature) circuit.  
 

10.

 

Connect 3 Bar (42.5 psi) supply of food grade CO

to the CO

inlet bulkhead fitting on the back of 

the unit.  Dispense sparkling water until only gas is flowing to the faucet to purge the system of 
trapped air.  WL7 FW should automatically refill the carbonator in approximately 30 seconds once 
the dispense button is released.  The injection pump will turn on 2 seconds after releasing 
sparkling dispense button. Premium Sparkling Water will not be produced until the system has 
reach cold set point.   

 

11.

 

It will take the heater approximately 10 minutes to heat the water to the factory set point of 87°C 
(187°F).    The hot status bar will flush when heater is on and be solid with heater off.  The hot 

status bar arrows indicate tank temperature 
from

 below 40°C (104°F) on far left to set 

point on the far right. 

 

 

Dispense a cup of hot water to ensure the 
temperature/odor/taste is acceptable.   

 

 
 
 

WARNING!  

HOT WATER CAN BURN OR SCALD. 

The

 WL7 FW Water Purification System 

produces Hot Water up to 95°C (203°F).

 Water above 52°C (125°F) can cause severe burns or 

scalding.  Hot water should be dispensed carefully into insulated container to avoid injury. 

 

12.

 

Once the 

WL7 FW Water Purification System

 ice bath builds a complete ice ring in approximately 

90 minutes depending upon environment.  The compressor will shut off once the ice ring has 
reached thickness ice sensor.   
  
The cold status bar will flush when 
compressor is on and be solid with 
compressor off.   

 

You can visually inspect the ice ring 

build 

through the access hole in the top of the ice bath if needed. The condenser at the rear of the unit 
will build heat as indication the refrigeration system is operating properly.  Route all hose away 
from direct contract with heat from the condensing coils at the back of the unit.      

Reviews: