background image

 

WL7

 

FW 

Manual 

                                                                  Page 74 ‐ Revision:  6‐11‐2019

 

WL7 FW INSTALLATION PROCEDURES 

 

13.

 

Dispense a cup of cold water to ensure the temperature/odor/taste is acceptable.    
 

14.

 

The sparkling chamber (carbonator) must be completely regenerated (emptied) a few times once 
the ice bath has reached set temperature and the drinking water line and sparkling chamber are 
cold.  Regeneration will clear the chamber of the initial air and water trapped during startup and 
ensure that premium sparkling water is produced.  Always use 3 Bar (42.5 psi) supply of food 
grade CO

and ensure bath has reached cold set point before regenerating sparkling water tank. 

 
The WL7 FW ice ring takes hours to completely melt off in ambient conditions and can be used to 
help reduced setup time in field if unit is prepared in shop and left operational prior to field 
installation.  The remaining ice ring will reduce cooling time at installation.      
 

15.

 

Dispense a cup of sparkling water to ensure the temperature/odor/taste is acceptable.  Sparkling 
output (carbonation level) can be tested if needed.    Additional information on Waterlogic 
Premium Sparkling Water can be found in this manual in sections: 

 

 

 

WL7 FW Principles of Operation ‐ Dispensing Sparkling Water  

 

Waterlogic Premium Sparkling Water Overview 

 

16.

 

Move the 

Waterlogic WL7 FW Water Purification System

 into its final operating position.  Be 

sure that a minimum of 2” clearance is maintained around both the sides and the back of the 
unit.  This is important to allow proper airflow and heat exchange of refrigeration system.  

 

17.

 

Level unit using the adjustable feet to level if necessary.  Never install on incline. 

 

18.

 

When the unit has reached its Hot Temp Set Point, ensure the heater cycles off.    

 

19.

 

When the unit has reached its Ice Bath Set Point, ensure the compressor cycles off. 

 

20.

 

Once the unit is at the target temperature(s), sample the water to ensure water meets 
expectations and additional rinsing or adjustment is not required.  

 

 

21.

 

Check the 

WL7 FW Water Purification System

 for any leaks.  External Leak Protection is always 

recommended. 
 

22.

 

Confirm all program settings are correct and reset the Bottle Counter to 
Zero if needed.  Enter maintenance mode and press and hold dispense 

button until bottle counter flashes on 
display and two beeps are heard.  Bottle counter will reset to zero 
once you release dispense button.  Exit maintenance mode by 
tapping dispense 5 times in 10 seconds. 
 
Always adjust Hot and Extra Hot Setting down when installing at 
elevation to avoid boiling hot tank. 

 

 

Reviews: