WL7 FW INSTALLATION PROCEDURES 

 

1.

 

Attach the water supply line to the 1/4” feed water inlet bulkhead fitting on the back of the unit.  

Waterlogic

 requires the use of a water pressure regulator.  Water feed pressure must be 

between 40‐60 psi and 2 lpm (0.5 gpm).   Turn on the water supply and check for leaks.     

 

2.

 

Check to ensure that both Power (Red) and Heater/Compressor (Green) Switches 
are in the 

O=OFF 

position.   

NOTE:

  Switch has internal LED that illuminates when placed in

 I=ON 

position.

 

 

 

3.

 

Connect the power cord to the back of the 

Waterlogic WL7 FW Water Purification System

 and to 

a 120 Volt 15 amp dedicated supply.  GFCI protection is recommended.

 

 

 

4.

 

Turn ON the Main Power (Red) Switch.  Leave Green Switch OFF. 

       CAUTION!  

NEVER TURN ON HEATER BEFORE FILLING HOT TANK. 

Green Compressor/Heater Switch must be in the O=OFF position while the hot tank is empty.  
Damage could occur within one minute and the overload (high limit) will require manual reset if 
heater is turned on with an empty hot tank.  

 

5.

 

WL7 FW

 will be in 

Start‐Up Mode

 whenever you turn ON the Main Power (Red) Switch and 

Heater/Compressor (Green) Switch is in the OFF position.     
The start‐up sequence should take approximately 5 minutes to complete when system is empty 
and status bar will flush indicating progress 

Start‐Up Mode

 process is as follows:  

 

Performs Self‐Diagnostic Checks 

 
 
 
 

 

Fills ice bath with cooling water and flushes filters into the bath. 

 
 
 
 

 

 

Fills sparkling tank (if equipped).  CO

supply does not need to be connected. 

 

 

 

 

 

Display will prompt installer to fill the hot tank to complete start up 

 
 
 
 