1.
Unpack the
Waterlogic WL400
and check exterior for damage.
2.
Remove Front Panel from Base Cabinet opening Top of Panel and
Removing Slide Bar.
3.
Remove
WL400
from packaging and place on top of base cabinet.
4.
Attach
WL400
to base cabinet with Locking Bolt provided.
a)
Remove screws from locking slides located under Front Cover adjacent to faucet.
b)
Unlock slides and open Top Cover of
WL400
. Top cover slides forward and then lifts.
c)
Locate wires and run them through.
5.
Connect Wires (Quick Connect Clips) on back of unit from Base Cabinet to
WL400
.
6.
Remove Pre-Carbon and Post-Carbon Filters and flush 5 gallons of water through each filter
separately.
7.
Reinstall Pre and Post Carbon Filters.
8.
Close RO Bypass and Bladder Tank
9.
On Back of Cabinet, connect 2 pieces of Tubing to RO
Drain Line and Water Out Line and run to external drain.
10.
Connect the power lead and insert it into the rear of the machine. Turn on
the Red Power Switch I=ON. Do NOT turn on the Green Heater /
Compressor Switch.
CAUTION!
NEVER TURN ON HEATER BEFORE FILLING HOT TANK.
Green Heater/Compressor Switch must be in the O=OFF position while the hot tank is empty.
Damage could occur within one minute and the overload (high limit) will require manual reset
if heater is turned on with an empty hot tank.
11.
Connect supply water to water in fitting on back of cabinet. Turn on the Water Supply and flush
RO system to drain for 4 hours. Water should be draining from both Water Out Line and Drain
Lines.
12.
After 4 hours, turn off Incoming Water. Connect Water Out Line from Base Cabinet to drain
water in fitting on
WL400
.
WL400
Operating, Installation, and Service Manual Page 34 - Revision: 5-29-2015