![background image](http://html1.mh-extra.com/html/waterlogic/wl2fw-firewall-series/wl2fw-firewall-series_manual_3657574079.webp)
WL2 FW
Manual
Page 78 – Revision EU05-07-17
PROGRAMMING INSTRUCTIONS
CHANGING HOT WATER MODE TO AMBIENT WATER
WL2FW Water Treatment Systems
comes with set to Hot / Cold, which can be changed to
Ambient / Cold settings. On the
Energy Saver PCB,
Move the Jumper on JP9 from Pins 1 and 2 to
Pins 2 and 3.
Unplug Power Cord and remove Top Cover to access Energy Saver PCB.
WL2FW Water Treatment Systems
comes with Hot and
Cold Water factory settings.
PCB Jumper JP9 in positions - Pin 1 and 2
1 2
Change to Ambient and Cold by moving PCB Jumper
JP9 to positions – Pin 2 and 3
2 3
Pin Numbers
1
2
3
Energy Saver PCB – P/N EN-6131 – WLCP PN 20-0075
Summary of Contents for WL2FW FIREWALL Series
Page 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Page 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Page 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Page 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Page 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Page 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...