WL2 FW
Manual
Page 60 – Revision EU05-07-17
6.
Hot Water Coming out of Faucet Vent Hole
Possible Reason
Solution
Too much water pressure.
Recommend 2.7 to 4 bar for the
WL2FW Water Treatment System
to
operate properly.
The correct input water pressure is critical to the
performance of the unit to allow solenoids to open.
Check water pressure at the inlet bulkhead with a water
pressure gauge.
Additional method of verification is to turn off water to unit
and press the dispense button. Does the solenoid open
without water pressure to the unit? Listen for solenoid to
activate, not button “click”.
Adjust water pressure to 2.7-4bar.
Improper tubing attachment from
the tank to faucet or vice versa.
Verify tubing is connected properly from tank outlets to
correct faucet attachments.
Hot Tank outlet hole is scaled over.
Inspect and Descale Tank as needed.
See Hot Tank Descaling Instructions that are included
further below in this Troubleshooting Section.
See instructional video on the Partner Area of the
Waterlogic.com website for more information.
Expansion chamber is not sealed
properly.
Replace the Hot Tank.
Summary of Contents for WL2FW FIREWALL Series
Page 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Page 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Page 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Page 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Page 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Page 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...