WL2 FW
Manual
Page 73 – Revision EU05-07-17
HOT WATER TROUBLESHOOTING INDEX
1.
Hot Water is not Hot 86°± -1.5°C (187°± 5°F)
Also includes related instructions for:
Disabling Energy Star Sleep Mode
Resetting the Hot Tank Overheat or High Safety Limit
•
Programming “Changing Hot Water Mode to Ambient Water Mode”
The Hot Temperature set point is 85°C (185
°
F) and is controlled by a thermostat on the side of the
Hot Tank.
There is a resettable overheat or high limit safety above the thermostat on the side of the Hot Tank
that will trip to prevent damage to the unit if the tank is dry heated (turned on without water in it).
The
WL2FW Water Treatment System
is programmable to make Cold / Ambient water – refer to
Disabling Sleep Mode instructions included further below in this Troubleshooting Section.
The
WL2FW Water Treatment System
does NOT have Extra Hot capability and the maximum hot
temperature is 87
°
C (189
°
F).
It typically takes 10 minutes for the 500W to heat the 1.5 litre (0.4 Gallon) of room temperature
(ambient) water to the 85
°
C (185
°
F) set point.
Possible Reason
Solution
No Power
Check that the Red Heater & Compressor switch is on.
Turn Red Heater & Compressor Switch on.
I = ON
Is unit in Energy Star
Sleep Mode?
If no water has been dispensed for 3 or more hours, unit goes into sleep
mode. Dispense hot water, wait 5 minutes, check temperature.
If unit still does not heat proceed to “No power to Heater elements” below.
If unit does heat but you would like to Disable Sleep Mode, refer to the
instructions included further below in this Troubleshooting Section
Hot Tank Overheat
Tripped
Overheat will “click” when pushed. The overheat is automatically reset
when pressed.
Overheat is a safety
feature to ensure the
See Resetting the Hot Tank Overheat or High Limit Safety Instructions that
tank does not
are included further below in this Troubleshooting Section
overheat.
Summary of Contents for WL2FW FIREWALL Series
Page 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Page 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Page 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Page 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Page 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Page 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Page 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...