10
11
Waterlogic 2000IT Technical Manual - Issue B, December 2013
Installation Procedures
1.
Mount the WL 2000IT on a firm flat surface with a 50mm air gap on both sides
and top so that it cannot topple or fall from a counter top.
2.
It is advisable that the water and electricity supply are within two meters of the
WL 2000IT and that the water isolation valve and power supply are accessible.
The WL 2000IT should not be installed using an extension lead. The water supply
should be from a potable source.
3.
Level the machine using the adjustable feet.
4.
Remove the top cover of the machine. If you are installing a freestanding machine
also remove the lower front cover. This is retained by two screws located under the
front edge at the bottom of the cover and two clips in the same location. Remove
the screws and push clips up to release. To gain access to the screws tilt the ma-
chine backward at an angle of 10 degrees.
5.
Make the water connection using an installation kit. Waterlogic recommends the
use of a pressure reducing valve, a shut off valve and a non-return valve. These
should be fitted before the water intake to the machine. Minimum operating pres-
sure for the machine to work suitably is 2.5 bar. The ideal operating pressure is at 3
bar. At pressures higher than 3 bar the machine will not function correctly and can
lead to leaks.
6.
Please flush the water supply pipe until it runs clear, before making the water
connection to rear of the machine.
7.
The power lead is located in a recess on the top packing cover of the machine re-
gardless whether it is a mini or a free standing model. Inspect the electrical socket,
the machine plug and the power cable for any transit damage. Now plug the power
lead into the back of the machine. As soon as you plug the machine into a suitable
power supply voltage will be available to the PCB and solenoid valves and you can
now start to flush water through the machine. Do not at this point turn on the heater
and compressor switch at the rear of the machine. This switch should only be turned
on once the hot tank is filled with water.
8.
The hot water temperature is set at 85°C and the cold water temperature is set
at 5°C at the factory. It is not possible to adjust the hot water temperature, but the
cold water temperature can be adjusted by regulating the thermostat situated at the
back of the machine. This thermostat is set at a specific point at the factory. This
point is marked out by a small dot situated on the outside of the thermostat. It is
advised that you do not adjust the cold thermostat past the factory set point of 5°C
as this may result in the system freezing.