Tested using flow rate=0.5 GPM; pressure=60 psi; pH=7.5 ± 0.5; temp.=20 ± 1.0 °C.

SPECIAL NOTICES

• The contaminants or other substances removed or reduced by this water treatment 

  system are not necessarily in your water.

• Do not use with water that is microbiologically unsafe or of unknown quality without 

  adequate disinfection before or after the system.

• System certified for cyst reduction may be used on disinfected waters that may contain 

  filterable cysts.

• This Class A system conforms to NSF/ANSI 55 for the disinfection of microbiologically 

  contaminated water that meets all other public health standards. The system is not 

  intended to convert wastewater or raw sewage to drinking water. This system is 

  intended to be installed on visually clear water.

  NSF/ANSI 55 defines wastewater to include human and/or animal body waste, toilet 

  paper, and any other material Intended to be deposited in a receptacle designed 

  to receive urine and/or feces (blackwaste); and other waste materials deposited in 

  plumbing fixtures (greywaste).

• Performance may vary based on local water conditions seconds.

WARRANTY

Waterlogic International (Waterlogic) warrants that the products delivered will be free 

from any defects in workmanship or materials. Further, the warranty provided here in 

applies, only when used within the products specifications and service life, from the date 

of installation, beyond which time or use Waterlogic is absolved of any and all liability for 

any use of the product. In the event of defect or non-conformity, buyer shall promptly 

notify Waterlogic in writing, supplying proof of purchase dates, installation dates, and will 

protect and retain the products for investigation, or Waterlogic is absolved of any and all 

liability for any use of the product. There are no other warranties, either merchantability 

or fitness, either expressed or implied.

FOR IOWA ONLY

The Manufacturer’s  PDS shall be given to the buyer by the seller and shall be signed 

and dated by the buyer and the seller prior to the consummation of the sales of the 

water treatment system and retained on file by the seller for a minimum of two years.

Seller _________________________ Date _______________________ 

Buyer __________________________ Date______________________

Operating Specifications

Filter Capacity

2,500 Gallons / 9,464 Liters

Lead Capacity

1,250 Gallons / 4,732 Liters

Maximun Flow Rate

0.34 GPM / 1.3 LPM

Feed Water Temperature

2 °C / 35 °F - 32 °C / 90 °F

Operating Temperature

5 °C / 41 °F - 30 °C / 86 °F

Working Pressure

0.26Mpa / 37.7Psi - 0.414Mpa / 60 Psi

Electrical Requirements

EU: 220-240V 50Hz / maximum 3.0 amps; 

USA: 120V 60Hz / maximum 6.2 amps 

UV Performance Data Table

Parameter

Log Reduction Average

Bacteria (R.terrogema)

7.4 Log

Virus (MS2)*

3.16 Log

Note: 2 Log reduction of MS2 is equivalent to 4 Log reduction of Poliovirus or Rotavirus 

Summary of Contents for Countertop Pure K-FU-00S20-00C1L-13-0-XXX

Page 1: ...ervice Guide Waterlogic Countertop Pure Kit K FU 00S20 00C1L 13 0 XXX includes sediment filters FT 0003 L00 XXX carbon filter FT 0006 L00 XXX UV lamp CT 2090 C Only for use with Waterlogic Countertop...

Page 2: ...for purchasing the Waterlogic Countertop Pure Kit Please read this manual before servicing the Countertop machine Index Declarations 3 Box contents 4 12 month servicing guide 6 Product disposal 16 Per...

Page 3: ...ons such as staff kitchen areas in shops offices and other working environments farm houses and by clients in hotels motels and other residential type environments bed and breakfast type environments...

Page 4: ...4 IN THE COUNTERTOP PURE KIT BOX YOU WILL FIND 1 Waterlogic sediment filter 2 Waterlogic carbon block filter CBC 3 Waterlogic Firewall UV bulb Box Contents...

Page 5: ...des a 1 micron carbon block filter with cyst lead reduction capabilities and a 13 Watt UV C lamp that requires periodoc replacement annually in most cases Please ensure you purchase only original Wate...

Page 6: ...nd UV lamp must be replaced at this service Some units may have screws holding the lid on that will need to be unscrewed before the lid can be removed This will be model dependant Screws will need to...

Page 7: ...point 1 3 Select the cold water icon until it lights up Whilst the cold water icon is lit select and hold the central dispense button when the water stops flowing release the button and continue to s...

Page 8: ...ne from under wall units to allow access This is why it is important you fit an extra 15 30cm of the flexible tubing from the water supply when installing the unit Please take care not to dislodge the...

Page 9: ...block filter assembly into its cradle with the filter loop on the left see picture F which enables the filter shape to perfectly fit the cradle profile 2 4 Push the filter firmly into place until the...

Page 10: ...tion see picture H H I 3 2 Remove the filter by pulling straight upwards on the filter loop see picture I 3 3 Insert the new sediment filter assembly into its cradle with the filter loop on the left s...

Page 11: ...ct the UV lamp connector by pressing in the clip on the side of the connector step 1 and pulling the connector towards the front of the machine step 2 see picture N M L UV protective cover UV protecti...

Page 12: ...to avoid breaking it ensure that it is fully vertical when you insert it and do not use excessive force 4 5 Insert the connector on the new UV lamp into the UV connector in the machine see picture Q P...

Page 13: ...making sure the two fixing lugs at the front are lined up with the grooves step 1 and then pulling the cover firmly towards yourself until it clicks into place step 2 see picture S If your machine ha...

Page 14: ...ng water Continue to hold the dispense button until 8 litres of ambient water has passed through the machine Once 8 litres has passed through release the dispense button and the water flow will stop T...

Page 15: ...be up to operating temperature after 8 10 minutes and the cold water will take between 60 90 minutes to cool 6 2 The water should now be taste tested if there is any hint of taste in the water then f...

Page 16: ...ducts are covered by the Waste Electrical and Electronic WEEE directive 2002 96 EC The symbol shown above denotes that the product should not be disposed of with general household waste Hand it in at...

Page 17: ...reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 NSF ANSI 53 NSF ANSI 55 Class A and NSFANSI P231 While testing was condu...

Page 18: ...Jinling Road Jinling Industrial Zone Chengyang District Qingdao 266111 Shandong P R CHINA TEL 86 532 87909132 Tested using flow rate 0 5 GPM pressure 60 psi pH 7 5 0 5 temp 20 1 0 C Operating Specific...

Page 19: ...erformance may vary based on local water conditions seconds WARRANTY Waterlogic International Waterlogic warrants that the products delivered will be free from any defects in workmanship or materials...

Page 20: ...pe you love drinking good water as much as we do Please let us know your thoughts by email to goodwater waterlogic com To speak to a Water Expert please refer to your Guarantee and After sales service...

Reviews: