21
NSTALLATION
I
The installation must be carried out by a suitably
qualified person, in accordance with the current
of the
the Scottish Development
o
This appliance should be wired into a 13 A double pole switched
fused spur outlet, having 3 mm contact separation and placed in
an easily accessible position adjacent to the appliance. The spur
outlet must still be accessible even when your oven is located in
connection, securing the cord in place with the
If you have to change the oven power cord, the earthing
version of the following.
o
UK Regulations and Safety Standards or their European
Norm Replacements.
o
Building Regulations (issued by the Department
Environment).
o
Building Standards (issued by
Department).
o
IEE Wiring Regulations.
o
Electricity At Work Regulations.
Electrical connection
Before connecting the appliance, make sure that the supply voltage
marked on the rating plate corresponds with your mains supply
voltage.
WARNING: THIS APPLIANCE MUST BE EARTHED.
its housing.
o
To connect the oven power cord, loosen and remove the cover
on the terminal block, in order to gain access to the contacts
inside. Make the
cable clamp provided and then immediately close the terminal
block cover again.
o
(yellow/green) conductor must always be 10 mm longer than the
line conductors.