8
Step 7. Mounting the Filtration Unit
1. While holding the V360 system in its intended mounting position, mark the holes for the
wall screws with the pencil
. Using a 1/8” bit, drill the pilot holes for the screws.
2.
(For V360 Single Filter systems)
Position the bracket and screw in the mounting screws
until snug.
3.
(For V360 Dual Filter or Triple Filter UF systems only)
Screw in the mounting screws
leaving ¼” protruding. Hang the system mounting bracket on the screws and tighten until
snug. If the unit is to be mounted on wallboard, use the plastic screw anchors supplied.
4.
(For V360 RO systems only)
S
crew in the mounting screws leaving ¼” protruding. Cut
the
¼” tube from the storage tank to the desired length by following the directions in Step 6.
Connect the tank
tube to the ‘to storage tank’ fitting at the rear of the RO system. See
Figure 1B if you are unsure of its location. Make sure that the tube is inserted all the way
into the fitting and the connection is secure. Hang the system mounting bracket on the
screws and tighten until snug. If the unit is to be mounted on wallboard, use the plastic
screw anchors supplied.
Step 6. Connect the System Tubing
1. Connect the red tube from the water supply adapter with the system push-on
‘water inlet’
fitting
, after cutting the ¼” red supply tube to the length required. Make sure tube cuts are
clean and square and the tube is fully inserted into the inlet fitting.
2. Connect the clear
¼” tube to the faucet tube adapter. Connect the other end to the ’to
faucet’ system outlet fitting after cutting the faucet tubing to the desired length. Make sure
tube cuts are clean and square and the tube is fully inserted into the fitting.
You may find that your unit does not have labels attached to indicate the water inlet and
faucet connections. Refer to Figure 1A to verify their location.