7
Step 5. Install the Drain Saddle Assembly
(V360 RO System only)
1. Select the location to install the drain saddle assembly. This is usually on the sink
drainpipe and needs to always be located above the “S” trap.
2. Position the drain saddle assembly in the selected location and mark the spot through the
outlet with a pencil or marker.
3.
Drill a ¼” hole at the marked spot. Strip the backing paper from the adhesive side of the
foam gasket and position on the inside of the drain clamp back plate, aligning the gasket
hole with the outlet. Attach the drain clamp back plates to the drainpipe, aligning the push-
on fitting with the drilled hole. Using the screws provided, tighten the clamp snugly. DO
NOT OVER TIGHTEN. See Figure 3 below.
4. You will find the drain tube is connected to
the
bottom of your RO membrane cartridge
(yellow) by a blue coded 90
elbow which has
the built-in Drain Line Flow Control (DLFC).
The drain tube may be inserted directly into the push-on drain clamp fitting, using
instructions in Step 8 below. Do not attach drain tube at this time.
Figure 3.
Step 6. Install the Tank Valve, Preparing the Storage Tank
(V360 RO System only)
Wrap the threaded storage tank nipple with two wraps of Teflon tape. Thread on tank shut-off
valve until snug. Using the wrench, turn an additional ¼ turn. DO NOT OVER TIGHTEN. Place
tank in its intended position and open the tank valve to the fully open position. Connect one length
of the clear PE tube to the tank valve by inserting the tube into the push-on fitting all the way.
Gently tug to assure a secure connection.