Waterite VECTAPURE 360 Installation And Owner'S Manual Download Page 7

 

Step 5. Install the Drain Saddle Assembly 

(V360 RO System only)

 

1.  Select  the  location  to  install  the  drain  saddle  assembly.    This  is  usually  on  the  sink 

drainpipe and needs to always be located above the “S” trap. 

 
2.  Position the drain saddle assembly in the selected location and mark the spot through the 

outlet with a pencil or marker. 

 

3. 

Drill a ¼” hole at the marked spot.  Strip the backing paper from the adhesive side of the 
foam gasket  and position on the inside of the drain  clamp back plate, aligning the gasket 
hole with the outlet.  Attach the drain clamp back plates to the drainpipe, aligning the push-
on  fitting  with  the  drilled  hole.    Using  the  screws  provided,  tighten  the  clamp  snugly.  DO 
NOT OVER TIGHTEN.  See Figure 3 below. 

 

4.  You  will  find  the  drain  tube  is  connected  to 

the 

bottom  of  your  RO  membrane  cartridge 

(yellow)  by  a  blue  coded  90

   elbow  which  has

  the  built-in  Drain  Line  Flow  Control  (DLFC). 

The  drain  tube  may  be  inserted  directly  into  the  push-on  drain  clamp  fitting,  using 
instructions in Step 8 below.  Do not attach drain tube at this time. 

 

Figure 3. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Step 6. Install the Tank Valve, Preparing the Storage Tank 

(V360 RO System only)

 

 

Wrap  the  threaded  storage  tank  nipple  with  two  wraps  of  Teflon  tape.    Thread  on  tank  shut-off 
valve until snug.  Using the wrench, turn an additional ¼ turn.  DO NOT OVER TIGHTEN.  Place 
tank in its intended position and open the tank valve to the fully open position.  Connect one length 
of  the  clear  PE  tube  to  the  tank  valve  by  inserting  the  tube  into  the  push-on  fitting  all  the  way.  
Gently tug to assure a secure connection.   

 

 
 
 
 
 
 

Summary of Contents for VECTAPURE 360

Page 1: ...FERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN ANNUAL PREVENTATIVE MAINTENANCE INSPECTION BY A WATER PROFESSIONAL IS RECOMMENDED TO ENSURE TROUBLE FREE AND CONTINUOUS OPERATION R2 ...

Page 2: ...o pass to its interior As the raw water passes across the surface of the filaments only clean water is allowed to pass through and collect in the filaments and continue on in the system while sediment and other contaminants are rejected and retained by the cartridge A reverse osmosis RO membrane is a semi permanent synthetic film that is spiral wound and separates raw water from product water perm...

Page 3: ...oduce A VECTAPURE 360 RO system will nominally produce 75 US gallons 285 litres of product water per day This output will be affected by system pressure concentration of dissolved salts in the raw water raw water temperature and other localized factors Normally you can expect the system to produce 7 or 8 litres of water per hour VECTAPURE 360 UF systems and inline filtration systems operate contin...

Page 4: ...One only 1 meter length clear of tube for connecting RO system to the storage tank One drain pipe saddle included in RO hardware kit The waste water drain tube has been factory attached to the RO membrane One preassembled blue coded 90 elbow with Drain Line Flow Control DLFC built in a the base of the yellow RO membrane cartridge Step 1 Selecting the System Location 1 Your V360 filtration system i...

Page 5: ...punch V360 RO installers will also need a drill bit Always wear eye protection when using an electric drill Step 3 Install the Cold Water Supply Faucet Adapter 1 Turn OFF the COLD water supply valve to your kitchen faucet 2 Turn ON the COLD water on your kitchen faucet to release all the pressure and completely drain the cold water until the water flow stops 3 Place some towels underneath the cold...

Page 6: ... less than 1 the faucet can be mounted directly to sink If the thickness exceeds 1 the faucet must be mounted directly on the countertop or a faucet with an extended shank must be used Tool substitution Use a 5 8 masonry bit to drill the concrete sink 4 If you have a porcelain enamel or ceramic sink it is strongly recommended that a professional install the faucet to avoid chipping and damaging th...

Page 7: ...lamp snugly DO NOT OVER TIGHTEN See Figure 3 below 4 You will find the drain tube is connected to the bottom of your RO membrane cartridge yellow by a blue coded 90 elbow which has the built in Drain Line Flow Control DLFC The drain tube may be inserted directly into the push on drain clamp fitting using instructions in Step 8 below Do not attach drain tube at this time Figure 3 Step 6 Install the...

Page 8: ...f the RO system See Figure 1B if you are unsure of its location Make sure that the tube is inserted all the way into the fitting and the connection is secure Hang the system mounting bracket on the screws and tighten until snug If the unit is to be mounted on wallboard use the plastic screw anchors supplied Step 6 Connect the System Tubing 1 Connect the red tube from the water supply adapter with ...

Page 9: ... take 1 3 hours or more Open the faucet and let the entire tank drain completely You may see dark carbon dust briefly flush from the carbon cartridge this is harmless and normal for the first flow of water through the cartridge Allow the system to re fill the tank Once completed your system is ready for use Section 3 Operation and Maintenance Operation of your V360 Filtration System is simple and ...

Page 10: ...hly Remove the replacement cartridge from its box and its sani sealed protective sleeve Remove the protective cap Make sure the correct cartridge is installed in its socket according to its colour Locate the alignment tab on the top of the cartridge there are two at 180 degrees from each other and align with the center front of the cartridge socket Push cartridge straight up into the socket while ...

Page 11: ...es installed to wrong fitting Install tubes per S 6 1 2 and 3 RO Low air charge in tank Charge to 7 10 psi or replace tank RO Tank full but no water flow Replace tank bladder ruptured RO Flow restrictor DLFC Check DLFC and replace if necessary RO Raw water TDS high Consult dealer may need pre treatment UF UF Membrane plugged Polyphosphate added to water Check with water authority and replace UF me...

Page 12: ...ecreases with age up to about 10 after 3 years Example 58 F 13 C and 50 PSI 3 4 bar measured in your home at the RO inlet From the chart below 5094 X 75 gallons 38 2 gallons 145 litres per day 38 2 gallons 24 hours 1 6 gallons 6 0 litres per hour production rate VISIT THE WATERITE TECHNOLOGIES WEBSITE FOR INFORMATION CONSUMER ONLINE REPLACEMENT PARTS AND PRODUCT UPDATES AT www waterite com DESCRIP...

Page 13: ...13 ...

Page 14: ...14 PAGE LEFT INTENTIONALLY BLANK ...

Page 15: ...15 PAGE LEFT INTENTIONALLY BLANK ...

Page 16: ...16 Waterite Technologies Inc 3 75 Meridian Drive Winnipeg Manitoba Canada R2R 2V9 204 786 1604 204 783 1599 fax www waterite com ...

Reviews: