Step 1.  Selecting the System Location

 

1.   The filter system should be mounted close to where the water line enters the building, such 

as the basement or adjoining utility room, to ensure all water used in the dwelling is treated. 

If you wish to tee off a water line to be used for outdoor hoses or an irrigation system, make 

sure  this  occurs  prior  to  the  filter  system.    Keep  in  mind  that  filter  housings  will  need 

periodic replacement and that easy access must be maintained.  Do not install in a location 

with high humidity, direct sun or a direct source of heat.     If you are installing a UV filter 

systems you will need a standard 110V plug nearby. 

 

2.   Additionally, choose an area that has adequate clearance all around the unit.   Allow 6” of 

clearance on either side and a minimum of 8” of clearance below the unit.  For UV models, 

allow  enough  clearance on  the  sides  to  extract  the  lamp  and  sleeve  in  the  stainless 

chamber, as these will require periodic cleaning and replacement. 

Summary of Contents for TriPlex DuPlex FS-BB Series

Page 1: ...es Combination Filter UV Systems THIS MANUAL IS TO BE LEFT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSON...

Page 2: ...ium and salts from the water No Unlike reverse osmosis systems inline filter systems do not filter out contaminants in solution They are designed to filter particulate colour oxidized iron algae cysts...

Page 3: ...Q What is the maintenance schedule for the system A good rule of thumb is to replace all filter cartridges every three months Dependent upon local water conditions and total water used cartridges may...

Page 4: ...stem Keep in mind that filter housings will need periodic replacement and that easy access must be maintained Do not install in a location with high humidity direct sun or a direct source of heat If y...

Page 5: ...PT National Pipe Thread 3 Mount the system bracket to the wall ensuring that the mounting holes are located into a stud masonry or reinforced wall section and that the bracket is level 4 Figure 2 show...

Page 6: ...d of 3 Remove the used cartridge and pour out the water remaining in the filter bowl Clean the inside of the bowl with warm soapy water Rinse the inside thoroughly before reassembling 4 Remove replace...

Page 7: ...his will allow any carbon fines from new carbon cartridges to be flushed clear While flushing check for plumbing or housing leaks and repair if necessary 4 When system flushing is complete close the o...

Page 8: ...PP Sediment Cartridge 10 BB 1mic PP10B01 Excelpure PP Sediment Cartridge 20 BB 1mic PP20B01 Excelpure PP Sediment Cartridge 10 BB 5mic PP10B05 Excelpure PP Sediment Cartridge 20 BB 5mic PP20B05 Excel...