background image

 

 

 

Section 3: Operation and Maintenance

 

 

!

 

DO NOT USE ANY WATER FROM THE SYSTEM UNTIL THE NEXT STEP IS 

COMPLETE.

 

 

1.  With  the  plumbing  complete  and  the  cartridges  loaded, your  filter  system is  ready  for  a 

pressure test.  If a bypass has been installed, turn off the bypass valve. 

 

2.  Open  a  faucet  nearby  in  the  plumbing  system.    Open  the  downstream (outlet)  shut-off 

valve  on  the  filter  system.    Slowly  open  the  upstream  (inlet)  shut-off  valve  until  fully 

open.   You will  hear water filling  the filter  housings and  will soon begin flowing from  the 

faucet that has been opened. 

 

3.  Let the system free-flow to the faucet for 10 minutes.  This will allow any carbon fines from 

new carbon cartridges to be flushed clear.  While flushing, check for plumbing or housing 

leaks and repair if necessary. 

 

4.  When  system  flushing  is  complete,  close  the  open  faucet.    Check  again  for  leaks 

around the filter system – it is now under full system water pressure.   Repair if necessary. 

 

Your Warranty

 

Keep your bill of sale and your warranty certificate, included in this kit.  This is needed to claim any 

parts  or  repair  service during the  warranty  period.   Read the  document completely for  warranty 

claim limitations and instructions. 

 

!

 

BE  SURE  TO  RETURN  THE 

WATERITE  WARRANTY  CARD 

LOCATED  IN  YOUR 

LITERATURE KIT.  THIS IS NECESSARY TO VALIDATE YOUR PRODUCT WARRANTY.

 

 

 

 

VISIT THE WATERITE WEBSITE FOR INFORMATION, 

CONSUMER ONLINE REPLACEMENT PARTS AND PRODUCT 

UPDATES AT:

 

 

www.waterite.com

 

Summary of Contents for TriPlex DuPlex FS-BB Series

Page 1: ...es Combination Filter UV Systems THIS MANUAL IS TO BE LEFT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSON...

Page 2: ...ium and salts from the water No Unlike reverse osmosis systems inline filter systems do not filter out contaminants in solution They are designed to filter particulate colour oxidized iron algae cysts...

Page 3: ...Q What is the maintenance schedule for the system A good rule of thumb is to replace all filter cartridges every three months Dependent upon local water conditions and total water used cartridges may...

Page 4: ...stem Keep in mind that filter housings will need periodic replacement and that easy access must be maintained Do not install in a location with high humidity direct sun or a direct source of heat If y...

Page 5: ...PT National Pipe Thread 3 Mount the system bracket to the wall ensuring that the mounting holes are located into a stud masonry or reinforced wall section and that the bracket is level 4 Figure 2 show...

Page 6: ...d of 3 Remove the used cartridge and pour out the water remaining in the filter bowl Clean the inside of the bowl with warm soapy water Rinse the inside thoroughly before reassembling 4 Remove replace...

Page 7: ...his will allow any carbon fines from new carbon cartridges to be flushed clear While flushing check for plumbing or housing leaks and repair if necessary 4 When system flushing is complete close the o...

Page 8: ...PP Sediment Cartridge 10 BB 1mic PP10B01 Excelpure PP Sediment Cartridge 20 BB 1mic PP20B01 Excelpure PP Sediment Cartridge 10 BB 5mic PP10B05 Excelpure PP Sediment Cartridge 20 BB 5mic PP20B05 Excel...

Reviews: