background image

 

 

 

 

Congratulations!

 

 

You have purchased the finest multi-cartridge water system 

available for your home.   It will provide you years of reliable 

service if properly installed, operated and maintained.   Please 

read this entire manual before attempting installation and 

operation.

 

 

Section 1.  Frequently Asked Questions

 

 

Before getting started, take the time to familiarize yourself with your new Waterite system by 

reading some FAQs listed below.  Call us or ask your dealer if you have any other questions 

about your system’s operation.

 

 

Q: How do the DuPlex™ and TriPlex™ Water Filter Systems differ from an ordinary water 

system?

 

Ordinary water filters generally use one cartridge to filter contaminants or particles from the water. 

DuPlex™  and  TriPlex™  systems  use  multiple  cartridges  in  series  to  filter  different  types  of 

contaminants at the same time, allowing users to select cartridge types to match the application 

requirement.  When the UV system is included, the filter system provides the added benefit of 

bacteria, virus and cyst control. 

 

Q: Will TriPlex™ or DuPlex™ systems remove hardness, sodium and salts from the water?

 

No.  Unlike reverse osmosis systems, inline filter systems do not filter out contaminants in solution. 

They are designed to filter particulate, colour, oxidized iron, algae, cysts, taste and odor.  Some 

specialized cartridges are available to soften water but these generally have low capacity and this 

job is best left for a regenerating water softener. 

 

Q: Does cartridge filtration remove bacteria? Cryptosporidium? Viruses?

 

Where known microbiological contamination exists, specialized pre-treatment is recommended to 

ensure a safe water supply to the water filter system.  Untreated contamination will cause pre- 

filters and other system components to become contaminated from exposure.    Cross 

contamination of the entire plumbing system may occur when the filters are changed or disturbed. 

An added UV system will act as an effective barrier when properly installed and maintained but 

should act as a secondary barrier only when know contamination exists. 

 

!

 

THIS WATER FILTER SYSTEM IS DESIGNED ONLY TO IMPROVE AESTHETIC PROPERTIES 

AND  IS  NOT  DESIGNED TO  ACT  AS  A  PRIMARY  BARRIER  TO  WATERBORNE 

MICROBIOLOGICAL OR TOXIC  CHEMICAL  CONTAMINATION.       WHERE    THESE 

CONDITIONS  MAY  EXIST  CONSULT  A  WATER  PROFESSIONAL TO  ENSURE  SUFFICIENT 

RAW WATER PRE-TREATMENT AND DISINFECTION.

 

Summary of Contents for TriPlex DuPlex FS-BB Series

Page 1: ...es Combination Filter UV Systems THIS MANUAL IS TO BE LEFT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSON...

Page 2: ...ium and salts from the water No Unlike reverse osmosis systems inline filter systems do not filter out contaminants in solution They are designed to filter particulate colour oxidized iron algae cysts...

Page 3: ...Q What is the maintenance schedule for the system A good rule of thumb is to replace all filter cartridges every three months Dependent upon local water conditions and total water used cartridges may...

Page 4: ...stem Keep in mind that filter housings will need periodic replacement and that easy access must be maintained Do not install in a location with high humidity direct sun or a direct source of heat If y...

Page 5: ...PT National Pipe Thread 3 Mount the system bracket to the wall ensuring that the mounting holes are located into a stud masonry or reinforced wall section and that the bracket is level 4 Figure 2 show...

Page 6: ...d of 3 Remove the used cartridge and pour out the water remaining in the filter bowl Clean the inside of the bowl with warm soapy water Rinse the inside thoroughly before reassembling 4 Remove replace...

Page 7: ...his will allow any carbon fines from new carbon cartridges to be flushed clear While flushing check for plumbing or housing leaks and repair if necessary 4 When system flushing is complete close the o...

Page 8: ...PP Sediment Cartridge 10 BB 1mic PP10B01 Excelpure PP Sediment Cartridge 20 BB 1mic PP20B01 Excelpure PP Sediment Cartridge 10 BB 5mic PP10B05 Excelpure PP Sediment Cartridge 20 BB 5mic PP20B05 Excel...