WARNING: 

 

If soldering copper pipes, do not allow heat near plastic or nylon threads 

or fittings. 

 

10. Remove the  chamber  end caps.  Note that the quartz sleeve has not been 

factory installed.  Remove it from its packaging. Use a soft non-abrasive cloth 

to handle the sleeve. Wipe off any debris or fingerprints prior to installing. 

Slide the quartz sleeve into the chamber until about 1/2” (1.25 cm) protrudes 

from the either end. Slide one of the black supplied O-rings over the lower end. 

Next, slide one of the white gasket rings on the sleeve (Fig. 8 bottom) Screw 

on the bottom end cap (Fig. 9). Do not tighten. Install the other black O-ring and 

white gasket ring over the open end of the sleeve on the chamber end that has 

the grounding screw attached. (Fig. 8 Top) Screw on the electrical end cap. 

(Fig. 10) Turning in opposite directions, hand-tighten both end caps at the same 

time. Once assembled, tighten each cap ¼ turn using a wrench or pliers, do not 

over-tighten. 

 

11. Remove the lamp from its protective packaging.  Clean lamp exterior with a 

clean  non-abrasive  cloth.  Be careful not to leave fingerprints on the lamp.  

Connect the 4-pin electrical connector to the pins on the UV lamp. (Fig. 11) 

Insert the lamp through the opening at the end of the electrical end cap until the 

electrical connection is inside the end cap.  

 

12. Loosen the set-screw on the side of the lamp plug cover, and place the cover 

over the ledge of the electrical end cap. Tighten the set-screw. (Fig. 12) 

 

13. Remove the nut on the grounding stud and place the grounding wire (green & 

yellow) onto the stud. Replace the nut and tighten. (Fig 13) 

 

14. Remove the transmittance sensor from its packaging. Ensure the O-ring is in 

place above the threads on the sensor end. Wipe the face of the sensor with a 

clean non-abrasive cloth to remove any debris or fingerprints. Screw the sensor 

into the middle port. Hand-t ¼ turn using a wrench (Fig. 14) 

 

15. Connect the electrical end of the sensor to the right-hand side 2 pin terminal on 

the ballast chassis. (Fig. 15) 

 

16. If the Optional solenoid is installed on the unit, connect the 3-pin  electrical 

connector supplied with the solenoid,  to the 3-pin  adapter on the right-side 

middle of the UV ballast. (Fig. 15) 

 

17. Ensure the valves on either side of the UV disinfection unit are closed. Open 

the main water supply valve. Open the valve on the discharge side of the 

disinfection unit. Slowly open the feed side valve (lower) on the disinfection unit. 

Check for leaks.  If any leaks are present, close valves and repair. 

 

18. Connect the UV power source to a 120v receptacle. Turn on the power switch 

on the side of the ballast. Wait for 5-10 seconds before the Lamp On will be 

indicated. It will take additional time before the green LED indicates the lamp is 

ignited with over a 40mj/cm

2

 UV intensity, and if installed, the solenoid will open 

only after the UV cm

2

 exceeds 40mj/cm

2

. The current mj/cm

2

 dosage, the Lamp 

Summary of Contents for Excelight EL08NSFAK

Page 1: ...R S MANUAL For Excelight Ultraviolet system model EL08NSFAK IMPORTANT READ AND UNDERSTAND THE TERMS OF THE MANUFACTURER S WARRANTY ON PAGE 14 OF THIS MANUAL FILL OUT THE WARRANTY REGISTRATION CARD WIT...

Page 2: ...HAVE DRINKING WATER TESTED REGULARLY UV RADIATION HAZARD NEVER OPERATE A UV LAMP OUTSIDE THE DISINFECTION CHAMBER EXPOSURE TO UV LIGHT CAN RESULT IN SERIOUS INJURY AND EXTREME BURNING OF THE SKIN AND...

Page 3: ...unit for anything other than its intended potable water application The use of attachments not recommended approved or sold by the manufacturer distributor may result in an unsafe condition Before doi...

Page 4: ...Transmittance Ballast Quartz Ultraviolet Thermal Control Sensor 120vac Sleeve Lamp Valve Adapter BALLAST AND DISPLAYS Function display mj cm2 Reset Transmittance indication Button Monitor Port 2 pin...

Page 5: ...the temperature does not fall below 4 C 40 F and the humidity level is low to prevent condensation on the chamber This unit functions optimally between 9 29 C 49 85 F 3 Use Teflon tape on all plumbing...

Page 6: ...e UV lamp and sensor Fig 2 6 Install the flow restrictor to the inlet port lower port The arrow on the restrictor indicates the direction of the water flow Fig 3 4 The arrow should be pointing towards...

Page 7: ...f the lamp plug cover and place the cover over the ledge of the electrical end cap Tighten the set screw Fig 12 13 Remove the nut on the grounding stud and place the grounding wire green yellow onto t...

Page 8: ...CONTACT YOUR LOCAL HEALTH AUTHORITY RESPONSIBLE FOR WATER SAFETY During the UV disinfection process the only place disinfection takes place is within the reactor chamber There is no residual disinfect...

Page 9: ...ve system operation timer The unit is available with an optional shutoff solenoid which will activate when there is an alarm turning off the water until the alarm is corrected The LCD display shows th...

Page 10: ...econds and then reconnect the AC power source If the failure was due to the Out of Limits AC Power the unit will re ignite the lamp and operate normally Total Running Hours The UV power source tracks...

Page 11: ...mbly to just expose the top of the UV lamp While holding the lamp base firmly disconnect the lamp 4 pin connector Gloves should be worn as the lamp base can be very hot Be careful not to drop the lamp...

Page 12: ...If there are leaks turn UV unit off close the shut offs disconnect the power to the unit and repair leaks SYSTEM REPLACEMENT PARTS EXCELIGHT NX System Replacement Components 1 Excelight NX8 UV Lamp S...

Page 13: ...35 200 Bacillus subtillis vegetative 11 000 Penicillum digitatum olive 88 000 Bacillus subtillis spore 58 000 Penicillum expensum olive 22 000 Clostridium tetani 22 000 Penicillum roqueforti green 26...

Page 14: ...00 Virus of Infectious Hepatitis 8 000 Staphylococcus aureus 7 000 YEAST Streptococcus faecalis 10 000 Baker s yeast 8 800 Streptococcus hemolyticus 5 500 Brewer s yeast 6 600 Streptococcus lactis 8 8...

Page 15: ...y is also subject to the conditions and limitations outlined under the heading General Conditions and Limitations below Warranty for Replacement Lamps and Parts Waterite Inc warrants replacement lamps...

Page 16: ...15 WATERITE INC Winnipeg Manitoba Canada www waterite com...

Reviews: