background image

1

Manual

     Thank you for your purchase of the Transmate DeChlorinator. Please read and understand 

this short operation manual. Our goal is to serve you, our customer. If you have any questions 

or improvement suggestions please call us at 1-800-426-9341. 

    

    

Romac Industries, Inc.

21919 20th Avenue SE • Suite 100 • Bothell, WA 98021

800 426 9341 • 425 951 6200 • Fax 425 951 6201 • www.romacindustries.com

deChlorinator Operations Manual 

08/30/2018 

Rev.

TM

Transmate

deChlorinator

TABLE OF CONTENTS

Solution Mixing ...........................................................................................................pg. 2
Components ...............................................................................................................pg. 3
Set-Up .......................................................................................................................pg. 4 
Operation....................................................................................................................pg. 5 
Toubleshooting ...........................................................................................................pg. 6 

Summary of Contents for Transmate deChlorinator

Page 1: ...uestions or improvement suggestions please call us at 1 800 426 9341 Romac Industries Inc 21919 20th Avenue SE Suite 100 Bothell WA 98021 800 426 9341 425 951 6200 Fax 425 951 6201 www romacindustries com deChlorinator Operations Manual 08 30 2018 Rev TM Transmate deChlorinator TABLE OF CONTENTS Solution Mixing pg 2 Components pg 3 Set Up pg 4 Operation pg 5 Toubleshooting pg 6 ...

Page 2: ...add Set Control Valve on Cl ppm mg l Vita D Chlor cups for maximum Cl value per 5 gal water NOTE Mixed solution cannot be stored overnight It will decrease in potency and will not dechlorinate If you Turn control valve toward 0 Turn control valve toward full open Increase the V D C mix amount Decrease the V D C mix amount You will Decrease the flow of feed solution Increase the flow of feed soluti...

Page 3: ...out from here FEED SOLUTION PORT The dechlorinating solution is fed into this port Flow range from 0 120gph Chlorinated Water In TM FEMALE CAM LOCK FITTING Used to connect deChlorinator to hydrant adapter VACUUM GAUGE Displays amount of vacuum created by water flow MALE CAM LOCK FITTING Quick fitting for connecting diffuser or exhaust hose GAS INJECTION PORT This port is used to introduce gas into...

Page 4: ...d 1 CONFIGURATION 1 Extension hose connected to the hydrant with the deChlorinator on the ground and a diffuser connected to outlet Connect female end of extension hose to hydrant or hydrant adapter In this case the hydrant adapter is connected to the end of the extension hose Connect female end of deChlorinator to male end of extension hose Connect diffuser to male end of deChlorinator CONFIGURAT...

Page 5: ...se NOTE NO Kinks NO Bends 3 ID minimum 20 ft long maximum CONFIGURATION 4 If you want to connect the deChlorinator to a fire hydrant using 20 feet of 3 ID exhaust hose connected to the deChlorinator outlet Follow these steps NOTE It is NOT recommended that the deChlorinator be connected directly to a hydrant with an exhaust hose connected to the outlet for use under 300 gpm Connect deChlorinator t...

Page 6: ...e valve is RED one turn BLUE two turns ORANGE three turns GREEN full open To install tubes on the Make Up Water Port and the Feed Soution Ports just push tube in Removal is just as easy To remove tubes push in on outside collar while pulling away from unit on tube Be sure not to force or overpull on the fittings Feed solution flow begins as needle starts moving Vacuum Suction Suction Suction Flow ...

Page 7: ...e tuned with the control valve This allows just enough dechlorinating solution to be fed to the water flow and extends the time between making up more batches of feed solution NOTE Frequently check chlorine content of the discharge water and adjust the feed solution as needed Control valve will fine tune the flow of the feed solution TM Transmate deChlorinator ...

Page 8: ...Elevate bucket above deChlorinator This will create a siphon You might have too much exhaust hose length too small an ID on your exhaust hose or too much restriction on your diffuser Shorten the exhaust hose length and increase the exhaust hose ID Increase the amount of water flow by opening hydrant more Increase the amount of dechlorinating reagent by scooping more into the feed solution mix Slow...

Reviews: