2

3

Solution Mixing

TM

    Needle Valve Setting  150-200 GPM  200-300 GPM  300-400 GPM  400-600 GPM  600+ GPM

    FULL OPEN      

22 gph (14 min)  45 gph (7min)  64 gph (5 min)  90 gph (3 min)  110 gph (3 min)

    3 turns              

17 gph (18 min)  34 gph (9 min)  48 gph (6 min)  68 gph (4 min)  83 gph (4 min)

    2 turns              

6 gph (55 min)  12 gph (27 min)  16 gph (19 min)  23 gph (13 min)  28 gph (11 min)

    1 turn                

4 gph (1.5 hour)  7 gph (44 min)  10 gph (31 min)  14 gph (22 min)  17 gph (18 min)

FEED SOLUTION CONSUMPTION CHART

Consumption in gallons per  (how many minutes to empty a 5 gallon bucket) hour

                                                           FLOW RATE in gallons per minute (GPM)

Vita-D-Chlor FEED SOLUTION MIXING AND

FEED SOLUTION VALVE SETTING CHARTS

This chart is good for water flow between 175 - 900 gpm

                                                                                            

0 - .5                                       1/4 cup                                        2 
.5 - 1                                       1/2 cup                                        2 
1 - 1.5                                     1/2 cup                                        3 
1.5 - 10                                   5 cups                                          2 
10 - 30                                    15 cups                                        2 
30 - 50                                    15 cups                                        3 
50 - 150                                  25 cups                                        Full open 
150 - 200                                34 cups                                        Full open 

If...                                     Then add...                            Set Control Valve on... 

Cl.(ppm, mg/l)                  Vita-D-Chlor cups                 for maximum Cl.  

 

 

value                                 per 5 gal water                         

NOTE: 

Mixed solution cannot be stored overnight. It will decrease in potency and will not dechlorinate. 

If you

Turn control valve 

toward 0

Turn control valve 

toward full open

Increase the V-D-C mix 

amount

Decrease the V-D-C mix 

amount

You will

Decrease the flow of feed 

solution

Increase the flow of feed 

solution

Be able to decrease the 

feed solution flow

Have to increase the feed 

solution flow 

And

Increase the amount of time 

between solution batch mixing.

Decrease the amount of time 

between solution batch mixing. 

Increase the amount of time 

between solution batch mixing.

Decrease the amount of time 

between solution batch mixing.     

                                                      

Keep in mind

You might not be adding enough feed 

solution to dechlorinate the water.

You might be using too much V-D-C mix 

and overdosing the discharge water.

More V-D-C will be used and less time 

spent making solution batches.  

Less V-D-C used. More time spent 

making solution batches.

Transmate

deChlorinator

Summary of Contents for Transmate deChlorinator

Page 1: ...uestions or improvement suggestions please call us at 1 800 426 9341 Romac Industries Inc 21919 20th Avenue SE Suite 100 Bothell WA 98021 800 426 9341 425 951 6200 Fax 425 951 6201 www romacindustries com deChlorinator Operations Manual 08 30 2018 Rev TM Transmate deChlorinator TABLE OF CONTENTS Solution Mixing pg 2 Components pg 3 Set Up pg 4 Operation pg 5 Toubleshooting pg 6 ...

Page 2: ...add Set Control Valve on Cl ppm mg l Vita D Chlor cups for maximum Cl value per 5 gal water NOTE Mixed solution cannot be stored overnight It will decrease in potency and will not dechlorinate If you Turn control valve toward 0 Turn control valve toward full open Increase the V D C mix amount Decrease the V D C mix amount You will Decrease the flow of feed solution Increase the flow of feed soluti...

Page 3: ...out from here FEED SOLUTION PORT The dechlorinating solution is fed into this port Flow range from 0 120gph Chlorinated Water In TM FEMALE CAM LOCK FITTING Used to connect deChlorinator to hydrant adapter VACUUM GAUGE Displays amount of vacuum created by water flow MALE CAM LOCK FITTING Quick fitting for connecting diffuser or exhaust hose GAS INJECTION PORT This port is used to introduce gas into...

Page 4: ...d 1 CONFIGURATION 1 Extension hose connected to the hydrant with the deChlorinator on the ground and a diffuser connected to outlet Connect female end of extension hose to hydrant or hydrant adapter In this case the hydrant adapter is connected to the end of the extension hose Connect female end of deChlorinator to male end of extension hose Connect diffuser to male end of deChlorinator CONFIGURAT...

Page 5: ...se NOTE NO Kinks NO Bends 3 ID minimum 20 ft long maximum CONFIGURATION 4 If you want to connect the deChlorinator to a fire hydrant using 20 feet of 3 ID exhaust hose connected to the deChlorinator outlet Follow these steps NOTE It is NOT recommended that the deChlorinator be connected directly to a hydrant with an exhaust hose connected to the outlet for use under 300 gpm Connect deChlorinator t...

Page 6: ...e valve is RED one turn BLUE two turns ORANGE three turns GREEN full open To install tubes on the Make Up Water Port and the Feed Soution Ports just push tube in Removal is just as easy To remove tubes push in on outside collar while pulling away from unit on tube Be sure not to force or overpull on the fittings Feed solution flow begins as needle starts moving Vacuum Suction Suction Suction Flow ...

Page 7: ...e tuned with the control valve This allows just enough dechlorinating solution to be fed to the water flow and extends the time between making up more batches of feed solution NOTE Frequently check chlorine content of the discharge water and adjust the feed solution as needed Control valve will fine tune the flow of the feed solution TM Transmate deChlorinator ...

Page 8: ...Elevate bucket above deChlorinator This will create a siphon You might have too much exhaust hose length too small an ID on your exhaust hose or too much restriction on your diffuser Shorten the exhaust hose length and increase the exhaust hose ID Increase the amount of water flow by opening hydrant more Increase the amount of dechlorinating reagent by scooping more into the feed solution mix Slow...

Reviews: