WATERGUARD Smart Stop 5648191 Installation Instructions & User Manual Download Page 9

INSTALLATION INSTRUCTIONS / USER MANUAL

9

3    If you use the sensor port on the wireless valve control:  

Test the safety function for the sensor cable by pulling it out.

 

 

•  A quick approx. 0.5 sec repeating audio signal is heard.

 

 

•  The LED indicatior in the RESET button vil alternate red and green.

 

 

•   Water in the tap will stop flowing. Control that the water starts flowing 

again when the sensor cable is put back in.

4  With a moist cloth wet one of the sensor points on the sensor tape. 

5  

The valve control will now indicate a leak with repeating audio signals approx every secont. The 
LED-indicator in the RESET button will emit a red light, and the valve will close the water.

6  Check that water stops flowing from the open tap.
7  Push RESET once to stop the audible alarm, the water should remain closed.
8  Wait one minute while thoroughly drying the moist sensor point.
9  Now, stop the alarm by pushing the central unit’s RESET button twice. 
 

The audio signal from the central unit will stop, and LED-OFF will change to LED-ON.

10 Control that the water still flows from the open tap.
11  Moisten the sensor point on the first wireless sensor. The drop in the Waterguard logo will light up 

red when moist i detected, and an alarm signal is being sent.

12  The water in the tap shall close, and the central unit will emit the number of beeps that 

corresponds with the triggered sensor. Now, wipe the sensor’s moist parts thoroughly!

13 The wireless central unit can now be reset by pusing the RESET button twice.
14 Check that the water starts flowing from the tap.
15  Repeat the procedure with the other wireless sensors, and be sure to dry all sensor points 

thoroughly after the test.

Installation instructions

Summary of Contents for Smart Stop 5648191

Page 1: ...INSTALLATION INSTRUCTIONS USER MANUAL SMART STOP Version May 25 2020...

Page 2: ...TALLATION INSTRUCTIONS USER MANUAL 2 1 valve 1 2 ART NO 5648191 1 valve 3 4 ART NO 5648193 1 valve 1 2 NC ART NO 5648195 1 valve 3 4 NC ART NO 5648197 This information is valid for these Smart Stop ty...

Page 3: ...to 2 dimensions A3 WTG 36C WIRELESS VALVE CONTROL NC Activates the solenoid valve when a leak is detected by the system 4 WIRELESS SENSOR ART NO 5648275 Battery powered wireless sensor 5 SPLIT CABLE...

Page 4: ...s a 230V AC 10A socket for dishwashers etc In case of a leak the valve control will interrupt the power to this socket NB THIS SOCKET IS NOT DESIGNED FOR CONNECTING WATER HEATERS Ref NEK 400 Norsk Ele...

Page 5: ...e will open and close very fast without influencing the waterflow The unit comes pre preogrammed with one exercising cycle every 24 hour This can be changed to the following frequency 1 time every 24...

Page 6: ...board ill 2 page 11 on the first wireless sensor for abt 1 second The central unit will emit audio signals and a small light diode will flash for abt 1 5 seconds This indicates a successful registrat...

Page 7: ...stalled after that 2 Filter MUST be installed where water can be contaminated by dirt or particles 3 See to that sealing material used does not enter the valve by assembly 4 The solenoid valve can be...

Page 8: ...n be cut to desired lengths Cutting it in two it can be connected to 2 units Test the functionality by moisting some of the sensor points before you start using the system START AND TEST Test the syst...

Page 9: ...the audible alarm the water should remain closed 8 Wait one minute while thoroughly drying the moist sensor point 9 Now stop the alarm by pushing the central unit s RESET button twice The audio signal...

Page 10: ...CE ENTRANCE KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN WASHING ROOM WASHING ROOM BATHROOM BATHROOM TECHNICAL ROOM TECHNICAL ROOM WIRELESS SENSOR WIRELESS SENSOR SENSOR TAPE SENSOR TAPE FILTER SIL...

Page 11: ...an alarm is triggered this is either due to a water leak or other factors such as cleaning with water etc 8 Localize the water leak or spill and dry up thoroughly 9 The alarm signal from the units ca...

Page 12: ...sh of RESET Take note of the number of signals which sensor has triggered before you reset the alarm 1 Remove the sensor from the wall bracket by pulling it approx 5mm upwards and then pulling it stra...

Page 13: ...e control is mounted Wireless sensor 1 is mounted Wireless sensor 2 is mounted Wireless sensor 3 is mounted Wireless sensor 4 is mounted Wireless sensor 5 is mounted Wireless sensor 6 is mounted Wirel...

Reviews: