WATERGUARD Smart Stop 5648191 Installation Instructions & User Manual Download Page 11

INSTALLATION INSTRUCTIONS / USER MANUAL

11

User manual

IN CASE OF ALARM

1    The system has two types of alarms when detecting a 

leak:

2   A wireless sensor detection will only be alarmed in the 

wireles control panel.

3   A leakage detected by the valve control’s sensor cable  

will be alarmed both on the valve control and on the 
control panel.

4   A leak alarm from a wireless sensor can only be reset/

cancelled on the control panel. An alarm from the valve 
control’s sensor cable must be reset/cancelled first on 
the valve control, then on the control panel. 

5   If there is water on the valve control’s sensor cable, the control will emit repeating 1-second alarm 

signals, and the Reset-button will display a red light. The solenoid valve now has closed the incoming 
water. Also the central unit will sound an alarm, and LED OFF will light up.

6   If there is water on a wireless sensor, only the control panel will sound an alarm and light up LED OFF. 

Also, the solenoid valve will close the water supply.

7   When an alarm is triggered, this is either due to a water leak or other factors such as cleaning with water 

etc.

8   Localize the water leak or spill, and dry up thoroughly.
9   The alarm signal from the units can be stopped by pushing the RESET-button once. The solenoid valve 

will still be closed.

10 In case of a real water leak, close the main stopcock and contact a plumber.
11 When the damage or spill is taken care of, be sure to carefully wipe off the wet parts of the sensor.
12 Push the RESET-button and the light will change from red to blue. The solenoid valve will open.

TESTING THE SYSTEM (at least twice a year)

1  Open a tap and let the water run.
2  With a wet cloth, moist one of the sensor-points. The valve should now close the water flow.
3  Make sure the water in the open tap has stopped.
4   With a dry cloth, dry the moist sensor point thoroughly. Push the RESET-button on the central unit to 

cancel the alarm. The alarm signal should now stop, and the LED should change from red to blue. The 
valve will open again.

5    Test all wireless sensors and sensor cables. NB: If the sensor port on the valve control is activated, the 

valve control must be reset before the central unit ca be reset!

RESET BUTTON

Summary of Contents for Smart Stop 5648191

Page 1: ...INSTALLATION INSTRUCTIONS USER MANUAL SMART STOP Version May 25 2020...

Page 2: ...TALLATION INSTRUCTIONS USER MANUAL 2 1 valve 1 2 ART NO 5648191 1 valve 3 4 ART NO 5648193 1 valve 1 2 NC ART NO 5648195 1 valve 3 4 NC ART NO 5648197 This information is valid for these Smart Stop ty...

Page 3: ...to 2 dimensions A3 WTG 36C WIRELESS VALVE CONTROL NC Activates the solenoid valve when a leak is detected by the system 4 WIRELESS SENSOR ART NO 5648275 Battery powered wireless sensor 5 SPLIT CABLE...

Page 4: ...s a 230V AC 10A socket for dishwashers etc In case of a leak the valve control will interrupt the power to this socket NB THIS SOCKET IS NOT DESIGNED FOR CONNECTING WATER HEATERS Ref NEK 400 Norsk Ele...

Page 5: ...e will open and close very fast without influencing the waterflow The unit comes pre preogrammed with one exercising cycle every 24 hour This can be changed to the following frequency 1 time every 24...

Page 6: ...board ill 2 page 11 on the first wireless sensor for abt 1 second The central unit will emit audio signals and a small light diode will flash for abt 1 5 seconds This indicates a successful registrat...

Page 7: ...stalled after that 2 Filter MUST be installed where water can be contaminated by dirt or particles 3 See to that sealing material used does not enter the valve by assembly 4 The solenoid valve can be...

Page 8: ...n be cut to desired lengths Cutting it in two it can be connected to 2 units Test the functionality by moisting some of the sensor points before you start using the system START AND TEST Test the syst...

Page 9: ...the audible alarm the water should remain closed 8 Wait one minute while thoroughly drying the moist sensor point 9 Now stop the alarm by pushing the central unit s RESET button twice The audio signal...

Page 10: ...CE ENTRANCE KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN WASHING ROOM WASHING ROOM BATHROOM BATHROOM TECHNICAL ROOM TECHNICAL ROOM WIRELESS SENSOR WIRELESS SENSOR SENSOR TAPE SENSOR TAPE FILTER SIL...

Page 11: ...an alarm is triggered this is either due to a water leak or other factors such as cleaning with water etc 8 Localize the water leak or spill and dry up thoroughly 9 The alarm signal from the units ca...

Page 12: ...sh of RESET Take note of the number of signals which sensor has triggered before you reset the alarm 1 Remove the sensor from the wall bracket by pulling it approx 5mm upwards and then pulling it stra...

Page 13: ...e control is mounted Wireless sensor 1 is mounted Wireless sensor 2 is mounted Wireless sensor 3 is mounted Wireless sensor 4 is mounted Wireless sensor 5 is mounted Wireless sensor 6 is mounted Wirel...

Reviews: