SYNERGY3D INSTALLATION MANUAL
Electrical Data
Model
Rated
Voltage
Voltage
Min/Max
Compressor
Int
Pump
FLA
Ext
Loop
FLA
Blower
Motor
FLA
Total
Unit
FLA
Min
Circ
Amp
Max
Fuse/
HACR
MCC
RLA
LRA
LRA**
038
208-230/60/1
187/254
23.8
15.2
83.0
30.0
1.07
5.4
4.0
25.7
29.5
40
038*
208-230/60/1
187/254
23.8
15.2
83.0
30.0
1.07
5.4
7.0
28.7
32.5
45
049
208-230/60/1
187/254
33.0
21.1
104.0
37.0
1.07
5.4
4.0
31.6
36.8
50
049*
208-230/60/1
187/254
33.0
21.1
104.0
37.0
1.07
5.4
7.0
34.6
39.9
60
064
208-230/60/1
187/254
42.3
27.1
152.9
54.0
1.07
5.4
7.0
40.5
47.3
70
072
208-230/60/1
187/254
46.3
29.6
179.2
63.0
1.07
5.4
7.0
43.1
50.5
80
09/24/13
Rated Voltage of 208-230/60/1.
HACR circuit breaker in USA only.
Local electrical codes overrule any wiring recommendations.
* With optional 1 HP ECM motor
**With optional IntelliStart
Min/Max Voltage of 187/254.
All fuses Class RK-5.