10
Waterford E61 Gas Fireplace Insert
INSTALLATION
Pilot assembly is now accessible for
steps 6) to 11).
3) Remove the door by lifting it slightly up and
off the front face. Remove the 7 nuts that
secure the front glass bracket holding the
center glass in place.
Remove the 7 nuts holding the Front Glass
Bracket to the front face.
CAUTION: Don't let the glass drop.
4) Carefully remove the logs and embers.
5) Remove burner. See diagram below.
Note: Use a magnetic type screwdriver if
possible.
6) Remove and discard the 3 pressure regu-
lator mounting screws (A), pressure regu-
lator tower (B) and diaphragm (C).
7) Insure that the rubber gasket (D) is properly
positioned and install the new HI/LO pres-
sure regulator assembly to the valve using
the new screws (E) supplied with the kit.
Tighten screws securely.
8) Pull off the pilot cap to expose the pilot
orifice.
9) Unscrew the pilot orifice with the allen key
and replace with the LP pilot orifice in the kit.
10) Remove burner orifice with a 1/2" wrench
and discard. Use a wrench to hold on to the
elbow behind the orifice.
11) Reinstall new burner orifice LP stamped
#50 and tighten.
12) Reverse steps 5) to 1).
13) Attach the label (Part#: 908-455) "This unit
has been converted to Propane" on top of
the Serial # decal.
14) Replace yellow "Natural Gas" label with red
"Propane" label
15) Check for gas leaks.
16) Check inlet and outlet pressures.
17) Check operation of flame control.
18) Check for proper flame appearance and
glow on logs.