Waterford Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each
unit thoroughly before it leaves our facility.  FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the  original
purchaser of a Waterford Product.

The Warranty:  Limited Lifetime
External casting, not directly in contact with the fire, such as hobs, sides, ash lips, legs, fronts and fire doors, are covered against cracks and warps resulting from
manufacturer defects, parts and subsidized labour* for three (3) years from the date of purchase and parts only thereafter.

The combustion chamber, heat exchanger, burner tubes/pans, logs, embers  and all gold plating (against defective manufacture only) are covered under the Limited
Lifetime Warranty for five (5) years for parts and subsidized labour* and parts only thereafter.

Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for three (3) years and parts only thereafter from date of purchase.

Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly
components, and gas valves are covered for one year parts and subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered
repairs and continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date
of replacement.

FPI venting components are covered parts and subsidized labour* for three (3) years from date of installation and parts only thereafter.

Conditions:
Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three
days of installation. Reported damage after this time will be subject to rejection.

Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent
provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated
for manufacturer defect.

The authorized selling dealer is responsible for all in-field service work carried out on your Waterford product. FPI will not be liable for results or costs of workmanship
from unauthorized service persons or dealers.

At all times FPI reserves the right to inspect product in the field which is claimed to be defective.

All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer
name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions:
This limited Lifetime Warranty does not extend to or include paint (charcoal units),  porcelain (including pinholes, scratches and minor shade mismatch), door or glass
gasketing or trim.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured.
ie. as products evolve, field modifications or upgrades will not be performed.

FPI will not be liable for travel costs for service work.

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the  terms of this warranty policy.

Refractory liners, gaskets, door handles, paint are not covered under the terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject  to misuse, improper installation, negligence
or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by
mechanical systems such as furnaces, fans, clothes dryer, etc.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from Waterford, may nullify
your warranty on this product.

Simpson Dura-Vent venting components are covered by Simpson Dura-Vent Inc. warranty.

* Subsidy according to job scale as predetermined by FPI.

Summary of Contents for EMERALD E61-LP

Page 1: ...ncy or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department 908 429a 04 21 05 EMERALD Gas Fireplace Insert Owners Installat...

Page 2: ...ree years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Waterford Fireplace WATERFORD GAS FIREPLACE INSERT This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance i...

Page 3: ...nstallation 9 Conversion from Nat Gas to Propane 9 Reduction to Lower Btu 11 Gas Pressure Test 11 ValveDescription 12 Aeration System 12 ShroudSurroundInstallation 12 Optional Door Grill Installation 13 LogInstallation 13 Optional Wall Thermostat Installation 13 OptionalRemoteControlInstallation 14 WiringDiagram 14 OPERATINGINSTRUCTIONS OperatingInstructions 15 LightingProcedure 15 ShutdownProcedu...

Page 4: ...ubulure d chappement basse à à é é é é 38 000 Btu h 11 14 Kw h 19 000 Btu h 5 57 Kw h 32 DMS 2 9mm 0 2000 ft pi 0 610m 27 000 Btu h 7 91 Kw h 13 500 Btu h 3 95 Kw h 40 DMS 2 49mm 0 4500 ft pi 0 1372m D bit Calorifique maximum D bit Calorifique minimum Dimensions de l orifice L altitude é é D bit Calorifique maximum D bit Calorifique minimum Dimensions de l orifice L altitude é é D bit Calorifique ...

Page 5: ... Btu h 8 50 Kw h 14 500 Btu h 4 25 Kw h 52 DMS 1 61mm 0 4500 ft pi 0 1372m Listed Report No VENT GAS FIREPLACE HEATER 476 1714 00 Oct 1999 Certified for Certifi e pour CANADA and U S A é ANSI Z21 88b 2003 CSA 2 33b 2003 CGA 2 17 M91 Tested to CAN FPI Fireplace Products International Ltd Delta BC Canada Made in Canada Fabrique au Canada This appliance must be installed in accordance with local code...

Page 6: ...ollow instructions and informa tion in the current CAN CGA B149 in Canada or the current National Fuel Gas Code ANSI Z223 1 in the USA regarding requirements for combustion and ventilation air GAS PIPE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure test ing of the gas supply piping system at test pressures...

Page 7: ...arbon See page 12 c Ensuring that the appliance is venting correctly MATERIALS REQUIRED No electrical power supply is required for the gas control to operate A 120 Volt AC power cord is hooked up to the fan switch and blower Plug 3 wire cord into a suitable receptacle Do not cut the ground terminal off under any circumstances When connected with 120 volts the appliance must be electrically grounde...

Page 8: ...eft rear corner of the unit The inlet fitting is a 1 2 female flare A separate gas shut off valve and a 1 8 IPS pluggedtappingshouldbeinstalledimmedi ately upstream of the connection to the appliance 3 Locate the center point where the vent will pass through the chimney above the appli ance Move the appliance into the exact location where it is to be installed Ensure that the Insert is level 4 The...

Page 9: ...ure with gear clamp 5 Install flashing 6 Insert both liners into chimney passing through the damper opening 7 Install termination cap 8 Connect the marked end of the liner to the inlet collar of the vent connector plate marked with an I seal connection with high temperature silicone Secure with gear clamp 9 Connect the 2nd liner to the exhaust collar marked with an E seal connection with high temp...

Page 10: ...asket D is properly positioned and install the new HI LO pres sure regulator assembly to the valve using the new screws E supplied with the kit Tighten screws securely 8 Pull off the pilot cap to expose the pilot orifice 9 Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit 10 Remove burner orifice with a 1 2 wrench and discard Use a wrench to hold on to t...

Page 11: ... 11 Check inlet and outlet pressures 12 Check operation of flame control Check for proper flame appearance and glow on logs GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa Disconnect piping f...

Page 12: ...stment 3 Pilot Adjustment 4 Thermocouple Connection 5 Main Operator 6 Outlet Pressure Tap Manifold Pressure 7 Inlet Pressure Tap Supply Pressure 8 PilotOutlet 9 Main Gas Outlet 10 Flange Securing Screw Holes 11 Alternative TC Connection Point 12 Thermoelectric Unit 13 Additional Valve Mounting Hole 4 Restart the heater and let it burn for approx imately15minutes Repeatuntilthedesired flame appeara...

Page 13: ... with the 2 screws 4 Place the right front log carefully sliding it down onto the right pins of the front burner See diagram 3 a Front Right Log Part 902 020 b Front Left Log Part 902 021 c Rear log Part 902 022 d Embers Part 902 151 1 bag e Lava Part 902 154 1 bag Part 560 935 for the set of three logs 1 Remove the logs from the box and carefully unwrap them The logs are fragile handle with care ...

Page 14: ...at is very im portant Run wires from the fireplace to that location use Thermostat Wire Table 2 Connect the wires as per the wiring dia gram below CAUTION Do not connect the millivolt remote control wires to the 120V wires 3 Install 3 AAA alkaline batteries in transmit ter and 4 AA alkaline batteries in the receiver Install the receiver and its cover in the wall Switch the remote receiver to remot...

Page 15: ...ll 3 Push in the gas control knob slightly and turn clockwise to OFF Do not force 4 Disconnect all electric power to the appli ance if service is to be performed FIRST FIRE The first fire in your stove is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time you use it with the fan on When...

Page 16: ...ILOT to OFF unless knob is pushed in slightly Do not force 2 Wait five 5 minutes to clear out any gas If you then smell gas STOP follow B in the safety information above on this label If you don t smell gas go to the next step 3 Turn knob on gas control counter clockwise to PILOT 1 Push in the gas control knob slightly and turn clockwise to OFF Do not force CAUTION Hotwhileinoperation Donottouch S...

Page 17: ... the logs DOOR AND GLASS GASKET If the door gasket requires replacement use only the proper replacement gasket available from your Waterford dealer GLASS REPLACEMENT Your Waterford stove is supplied with high temperature 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an aut...

Page 18: ...ound wire from the fan bracket 3 At this point you should disconnect the gas at the valve 4 Carefully remove the logs embers and rockwool 5 Remove burner Note Use a magnetic type screwdriver if pos sible 6 Remove all 18 screws holding the burner tray assembly in place 9 Undo the quick drop out thermocouple nut on the valve with a 9mm metric wrench 10 Remove the Piezo ignitor wire and push button a...

Page 19: ...ssy 77 270 520 P Fan Assembly 79 270 019 RearPanel 910 157 P Fan Blower 99 W843310 TerminalStrip 100 Base Plate 101 591 187 Firebox Baffle 102 Firebox 103 Heat Exchanger Assy 104 FlexPipe 105 Transition Box Assy 106 Gasket Transition Box 107 910 233 Fan Auto ON OFF Thermodisc 108 Thermodisc Bracket 109 Stove Top 110 Top Face 111 Insulation of Vent 113 Adaptor Holding Bracket Right 114 Insulation H...

Page 20: ...9 270 056 ControlPlate 30 W310770 Fan Speed Control Rheostat 120 V 32 904 656 Blanking Plug for Strain Relief 33 910 822 Power Cord 120 V 910 721 High Temp Wire Harness Main Switch 910 687 High Temp Wire Harness Motor Connect 910 718 High Temp Wire Harness Fan Valve 35 270 055 Switch Box 36 Washer 1 4 Flat 37 Screw 1 4 20 x 1 1 4 Pan Head Phillip 40 W310191 Top Grill 41 W310321 Lower Hob Heat Shie...

Page 21: ...tHolder 68 W840470 Pilot Assembly Gasket 78 651 580 Burner Assy NG LP 80 260 565 Adjustment Gear Assy 81 904 565 Hex Key 3 16 AF 82 630 009 Burner Tray Air Passage Gasket 83 630 008 Burner Tray Firebox Gasket 84 Front Support 87 560 935 Log Set 88 902 182 Log Top 90 Valve Mounting Bracket 92 270 036 Valve Gasket 93 Valve Support 94 904 658 Gas Inlet Flex Line 904 688 Orifice 32 NG 904 641 Orifice ...

Page 22: ..._____________________________________________ ____________________________________________________________________________ _____________________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ _____________________________________...

Page 23: ...e replaced component has been returned to FPI and evaluated for manufacturer defect The authorized selling dealer is responsible for all in field service work carried out on your Waterford product FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defectiv...

Page 24: ..._______________________________________________________ Printed in Canada Waterford fireplace products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door Waterford Irish Stoves is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Waterford Product See th...

Reviews: