background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pool Heat Pump

 

| Pg 16

 

 

OPERATION OF YOUR POOL HEAT PUMP 

Protection Devices 

 
The integrity and performance of your pool heat pump and its components are protected by 

internal  safety  controls.    In  normal  use,  your Waterco  unit  should  never  reach  the  thermal 

protection  level.    However,  if  it  should  happen,  you  should  identify  the  stated  code  on  the 
temperature display and refer to the section “Service Analyser Codes”.

 

 

       

IMPORTANT 

 

 

Functioning of Timer Controlling your Pool Pump 
 

Note:  This  option  could  be  install  with  all  our  product  by  following  our 
recommendations.  
 
When a timer is use on a pool pump the unit will stop on the flow switch protection 
and the digital displays will show nFL until the timer restart the pool pump. 
 
IMPORTANT: If you using this option take note than the unit will be heat the pool only 
when the timer allowed the pool pump to work. 

 

 

 

Adjustment of the Bypass Valves 

 
The adjustment may vary according to pool pump size and ambient temperatures. 

 

ATTENTION:  IT  IS  VERY  IMPORTANT  THAT  THE  BYPASS  VALVES  ARE  SET  AS 
DESCRIBED BELOW FOR THE CORRECT FUNCTION OF YOUR POOL HEAT PUMP. 

 
 

CLOSED

 

OPEN

 

OPEN

 

INLET 

VALVE POSITION 

 

POOL HEAT PUMP 

VALVE POSITION 

 

POOL HEAT PUMP 

VALVE POSITION 

 

POOL HEAT PUMP 

INLET 

INLET

 

OUTLET 

OUTLET 

OUTLET 

When the pool water 

temperature is between 65 

°F (18 °C) and 70 °F (21 

°C), please adjust the 

bypass valve as shown. 

 

Approx. 60% of the water 

is circulating in the unit. 

When the pool water 

temperature is between 70 

°F (21 °C) and 78 °F (26 

°C), please adjust the 

bypass valve as shown. 

 

Approx. 80% of the water 

is circulating in the unit. 

When the pool water 

temperature is above 79 

°F (26 °C), please close 

the bypass valve as 

shown. 

100% of the water is 

circulating in the unit. 

 

 
 
IMPORTANT  :  If  your  unit  does  not  stop  on  the  nFL  code  but  in  HP  code  your  flow  
switch  can be adjust  to  result  this  situation.  This  adjustment was not covered  by  the 
warranty.

 

 

 

 

 

Installation of a remote control

 

 
 

Note:  This  system  could  be  install  with  all  our  product  by  following  our 
recommendations.  

 
 

When a remote control is use on your pool heat pump the unit stop completely, when the unit 
was  stopped  by  the  remote  control  (blank  electronic  control)  until  the  remoter  control  will 
restart the system. 
 
 

IMPORTANT  :  If  you  would  like  to  use  this  system  it  must  be  install  by  an  authorize 
service center otherwise warranty could be avoid. 

 

 

Example: 

 

If you program a cycle of 8 hours of your pool pump (twice cycle of 4 hours) the unit will be 
allowed to heat the water only in this period. If you have program your electronic control at 

82  °F  (28  °C)

  and  the  temperature  of  the  pool  is 

70  °F  (21  °C)

  the  time  to  reach  the 

temperature require will be dr

amatically extended. That’s why we strongly suggest at the 

beginning  of  the  season  to  not  use  the  timer  until  the  desire  temperature  will  be  reach 
before using this timer. 

 

 

Summary of Contents for Ultra

Page 1: ...t Une installation inadéquate annulera la garantie Notice to Installer Avis à l installateur This manual contains important information about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owner operator of this equipment Ce manuel contient des informations importantes sur l installation l exploitation et l utilisation s...

Page 2: ...___ Compressor Starts and Stops ____________ There Is Water Around the Pool Heat Pump _ Pool Heat Pump Has Ice Formed On the Evaporator Coil _________________ Pool Heat Pump Is Not Heating ___________ Analysis Chart ________________________ Circuit Breaker Trips ___________________ Pool Heat Pump Is Noisy ________________ The Temperature Shown on Pool Heat Pump Is Not the Same than the Pool Thermo...

Page 3: ...ded for proper operation and heating Please refer to the section Location on the following page IMPORTANT Usage of Chemical Products Never add liquid chlorine granular chlorine or slow dissolving tablets pucks into the skimmer basket This high concentration of chemicals should be avoided Water quality standards that must be strictly adhered to Warranty can be voided if not maintained within these ...

Page 4: ...ir is pulled through the evaporator coil and discharged through the top or front grill Clearances should be allowed in front and around the unit for unrestricted air discharge and service access See Figure 1 and Figure 2 Re circulation of cold discharged air back into the evaporator coil will greatly reduce the unit s heating capacity and efficiency Pool Heat Pump Pg 06 No obstruction above Pool H...

Page 5: ... MUST be installed between the pool heat pump and any automatic chlorinator to prevent highly chlorine concentrated water from flowing back to the pool heat pump when the pool pump is not running 2 Units that are located below the water level of the swimming pool may require the pressure switch to be adjusted This can be checked by the following method Switch ON the water pump and the pool heat pu...

Page 6: ... these systems may leak stray voltage and currents into the water causing severe electrolysis This dramatically shortens the life of the pool heat pump and will void the warranty NOTE Bonding to pool pump is not required for above ground pool pumps but all other equipment must be bonded Pool water temperature must be above Atmospheric conditions must be above Model Ultra Reversible XLR All others ...

Page 7: ...g back to the pool water temperature when all keys remain untouched for 5 seconds To change the temperature display from Fahrenheit F to Celsius C press the button C F The led below the F or C will be lit to indicate the current selection Note The pool heat pump will stop working when the programmed temperature is reached OPERATION OF YOUR POOL HEAT PUMP Pool Solar Blanket A pool solar blanket sho...

Page 8: ...e XLR Electronic Control with Diagnostics Functioning of your Electronic Control with Diagnostics and Reversible XLR Electronic Control with Diagnostics OPERATION OF YOUR POOL HEAT PUMP Temperature Calibration It is possible to have a temperature variation between the water in the swimming pool and the reading of the pool heat pump temperature probe sensor Example the water in the pool is 26 ºC 80...

Page 9: ... 70 F 21 C please adjust the bypass valve as shown Approx 60 of the water is circulating in the unit When the pool water temperature is between 70 F 21 C and 78 F 26 C please adjust the bypass valve as shown Approx 80 of the water is circulating in the unit When the pool water temperature is above 79 F 26 C please close the bypass valve as shown 100 of the water is circulating in the unit IMPORTAN...

Page 10: ...the pool heat pump s heat exchanger in preparation for winter 4 Once the piping is disconnected the pool heat pump s heat exchanger MUST be emptied the use of a water vacuum cleaner is strongly recommended or if you do not have this tool you can tilt the unit 75 until all the water is out 5 It is recommended that the pool heat pump s heat exchanger is rinsed out with a gentle water spray at the in...

Page 11: ...was condensation which is normal TROUBLESHOOTING Nothing Is Working but the Electronic Control Displays Digits or a Code 1 Identify the analyser code that the electronic control displays and refer to the section Service Analyser Codes 2 If the electronic control displays digits make sure that the electronic control is programmed correctly refer to the section Operation of your Pool Heat Pump and r...

Page 12: ...s free of debris and leaves 3 If the evaporator is dusty or dirty clean it with a light spray of water and allow it to dry do not use high pressure it may damage the evaporator fins 4 When the unit is dry you may switch it back ON from the circuit breaker 5 Ensure that the clearances around the unit are respected 6 When the unit has been switched ON ensure the fan motor is working fan blades will ...

Page 13: ...s coming from the pool heat pump and not from other equipment which will not be covered by the warranty e g noise coming from the bypass valve pool pump etc 3 An improper installation may cause this situation it will need to be corrected by the owner This situation is not covered by the warranty The Temperature Shown on the Pool Heat Pump Is Not the Same than the Pool Thermometer It is possible to...

Page 14: ...ure the pool pump is switched ON Press ON OFF to restart the pool heat pump On new installations ensure the installation instructions were respected Check that the pool water level is correct that the pool pump is filled with water to the rim and that water is flowing correctly through the pool pump to the pool heat pump Check swimming pool and pool pump skimmer baskets and the drain at the bottom...

Page 15: ...ics and reversible XLR electronic control with diagnostics Problem Action Remedy Problem Low refrigerant level in the pool heat pump or the low pressure safety control is defective Atmospheric conditions as well as the pool water temperature should not be below the minimum operating temperatures as stated below in order to obtain efficiency and avoid codes from appearing on the electronic control ...

Page 16: ...tion stated in this section Warranty will only cover manufacturing defects All service call requests which are not of this nature must be paid by the purchaser to the service company authorized by Waterco Warranty service is to be completed by an authorized Service Center authorized by Waterco Where applicable in home service will be made available only in areas where a contracted service provider...