10 I
electrochlor Mineral Chlorinator
2. To access the electrochlor for connection of cabling and sensors, there are screw
wells in each corner of the front panel. To open the panel, insert a flat blade screw
driver and half turn anti-clock wise to release the spring loaded locking pin. ensure
the pins are fully released prior to opening the hinged front panel.
Electrochlor Mineral Chlorinator Power Outlets/Inputs
The electrochlor has the following input/output connections:
1. A gPO for the pool pump or auxiliary equipment (AuX1) with a maximum current
output of 7.0A and 240V
2. A gPO for a pool light or auxiliary equipment (AuX2) with a maximum current
output of 1.0A and 240V
3. A 24VAC jack socket to supply power to valve actuator with a maximum current
input of 2.0A
4. Provision for 2 cables input/output for a variable speed control cable and for low
chlorine/spa signal cable (dry connection)
POOL PUMP / AUX1 LIGHT LED / AUX2
240V AC 7.0A MAX. 240V AC 1.0A MAX.
JACK SOCKET
24VAC 2.0A IN
resetable
Fuse