30 I
electrochlor Mineral Chlorinator
k. diagnostics Menu:
The diagnostic menu allows the user to quickly evaluate the current state of
the electrochlor. It provides a picture of all the functions that are active at any
given the moment.
To access to the diagnostic menu, rotate the wheel until you find the
dIAgNOSTIC menu and press the wheel to select. See below figure. Press the
wheel to enter.
The menu allows the user to get the current status of the following parameters:
Parameter
Status
Active relay
electrolytic Cell
(Cell A/b)
ON
OFF
Valve
ON
OFF
Pool Pump
ON
Off
Flow detection
detected
No detected
light/AuX2
ON
OFF
low Chlorine
Activated
deactivated
AuX1
ON
OFF
Hi Current
electrochlor indicating that is operating at current output
higher than the maximum expected.
High Salt
electrochlor indicating high salt level in pool water.
low Salt
electrochlor indicating low salt level in pool water.
Pump dry1
Pump tried to start but no water flow was detected through
the electrolytic cell.
Pump dry2
Pump tried to start a second time but no water flow was
detected through the electrolytic cell.
Cell Swap
Indicates the last time the salt cell reversed it polarity.
run Hours
Indicates the total time the electrolytic cell has been active.
low Salt Hrs
Indicates the number of hour the electrochlor has been
operating with a detected low salt condition.