20 I
electrochlor Mineral Chlorinator Plus
I 21
electrochlor Mineral Chlorinator Plus
Figure 11.1 pH Settings Menu
Figure 11.2 pH Calibration Menu
Figure 11.3 Calibration pH Sensor
11. CALIBRATING THE SENSOR
This step requires a pH 7.00 reference solution (Waterco P/N 60121387). This step
requires the sensor to be removed from its saddle clamp. It is also important to
disconnect/stop the pump while performing this operation.
With the electrochlor On, push the wheel and navigate to pH, select this option
and using the wheel navigate to Calibrate and press enter.
Table 10.1 Reference pH Settings for Different Pool Sizes
Should any adjustment be required, adjust the desired set point in increments of
0.1. The proportion (%) can be adjusted as desired. Allow the pool to circulate for
48 hours before testing and adjusting again.
Pool Size
Range
Proportion (%)
Response rate
< 20kl
7.2-7.6
5%
Slow
40-60kl
7.2-7.6
50%
Average
> 80kl
7.2-7.6
100%
Fast