To access the electrochlor for connection of cabling and sensors, there are screw wells
in each corner of the front panel. To open the panel, insert a flat blade screwdriver and
half turn anti-clock wise to release the spring-loaded locking pin. ensure the pins are
fully released prior to opening the hinged front panel.
Electrochlor Mineral Chlorinator Power Outlets/Inputs
The electrochlor has the following input/output connections:
1. A GPO for the pool pump or auxiliary equipment (AuX2) with a maximum current
output of 7.0A and 240V.
2. A GPO for a pool light or auxiliary (AuX1) with a maximum current output of 1.0A
and 240V.
3. A 24VAC jack socket to supply power to valve actuator with a maximum current
input of 2.0A.
4. Provision for 2 cables input/output for a variable speed control cable and for low
chlorine/spa signal cable (dry connection).
The PUMP socket outlet in the base of the Power Pack is dedicated
to the filtration pump only. Do not use a double adaptor to connect
another pump as this will overload the system and void warranty.
Warning
resetable
Fuse
bottom View electrochlor Mineral Plus Chlorinator
08 I
electrochlor Mineral Chlorinator Plus
I 09
electrochlor Mineral Chlorinator Plus